P09 – Boiler default settings
Shows currently selected parameter,
restore default settings:
1 - power 100%,
2 – pump operating time 10min.,
3 – PID 3,
4 – CH temperature 70°C,
5 – hysteresis 6°C,
6 – HUW temperature 50°C (AsD model only),
go to P10 function.
Note: upon selecting P09 function, boiler automatically enters bleeding mode – please wait 300 seconds for
it to start operating properly.
P10 – Hygienisation (AsD model only)
HIG sign shows,
start process,
stop process.
Note: hygienisation function increases HUW
temperature to 70°C level for one hour. Function operation is signalized by lower line blinking.
Do not remove boiler external metal
casing once device remains turned on
.
In case boiler is activated by mistake with no water inside, wait until heaters cool down, fill device with
water and switch it on again. Under no circumstances fill device with cold water when heaters are still hot!
Once water in central heating system is heated, system should be bled once again (special attention must
be paid to the bleeding of the central heating pump and boiler air vent).
Elterm boilers are equipped in
AntiStop function
. Automatics turns the pump on for one minute once
every 14 days, what prevents it's rotor from seizing. AntiStop operates independently from on/off mode.
It is therefore highly recommended to keep boiler in off mode (red diode visible) in off-heating season -
in this mode device uses just 0,5W!