SETTINGS
Make sure the boiler is connected to electrical system in accordance with ELECTRICAL ASSEMBLY section.
1.
Red diode is on, heating is off and boiler in stand-by mode –
recommended mode in off-heating season
2. Press and hold power button for 5 seconds, green diode appears
3. LED display shows number 300 and starts the countdown. This process cannot be skipped – during this
time only central heating pump is activated, heaters remain idle. 300 seconds should be sufficient for
bleeding boiler and installation, if it isn’t - please turn the boiler off and on again to repeat activity.
4.
For AsD model only
. LED display shows number 50 – it represents current HUW temperature set on
boiler (bottom line visible on display).
Increase required temperature,
decrease required
temperature,
confirm required temperature,
go to CH temperature setting.
5. LED display shows number 20 – it represents current CH temperature set on boiler (upper line visible on
display).
Press once – temperature read starts to pulse,
increase required temperature,
decrease
required temperature,
confirm required temperature,
go to P01 function.
P01 – Boiler power – manual distribution
Shows current boiler power setting,
increase power (67%, 100%),
decrease power (67%, 33%),
confirm setting (100% is recommended),
go to P02 function.