Faults
Message
Description, process
I1-Alarm
I2-Alarm
The encoder connected does not supply any data
at times which may be invoicing-relevant.
b) Warnings:
Data restore DL230 batteries failed intermittently. As a result of
this, the time has not changed and measurement
acquisition has failed. All data has been saved.
This message appears when the battery is changed
and the old batteries are removed before the new
ones are connected. (see chapter 7.2, page 87).
Process using parameterization program "enSuite":
Set the DL230 clock
Clear the status register
Outp.1 Error
Outp.2 Error
More pulses need to be sent to the named output,
than its programming permits.
To eliminate the cause of this problem, use the
"Ensuite" parameterization program to
either reduce the cp value of the output
or increase the output frequency.
In both cases, the change must be aligned with the
device connected to the DL230.
I1-Warning
I2-Warning
The encoder could not be read at the end of the
measurement period. The flow recording at this
point is invalid.
Update error An error in the cached software image was found
prior to the software update.
Softw. error
This message is used for factory diagnostics.
Please contact the Elster customer service team
(see chapter 1.3 "Customer service").
Summary of Contents for DL230
Page 1: ...Operating manual Data Logger DL230 ...
Page 8: ......
Page 105: ...Appendix 105 English manual 73 022 387 ...
Page 106: ...106 Appendix 9 2 EC Declaration of Conformity ...
Page 107: ...Appendix 107 9 3 ATEX Type Examination Certificate 9 3 1 Associated apparatus for Zone 0 1 ...
Page 108: ...108 Appendix ...
Page 109: ...Appendix 109 ...
Page 110: ...110 Appendix ...