Operation
the device into operation (
chapter 5.3.1 "Configuration of
measurement parameters").
6.4.2.2 Vo1 and Vo2 – Original meters of the respective inputs
This meter is only available in encoder mode. It shows the original
meter reading of the respective meter which was transmitted by the
encoder. This means that Vo is always automatically on the state of
the meter and cannot be changed.
6.4.2.3 Time – Date and time
The time displayed is updated every 900 seconds in battery
operation and naturally this takes place immediately when switching
on the display. In mains operation and during communication,
updating takes place every two seconds.