Data Logger DL210
62
Elster-Instromet GmbH
3.3.7 Description of values shown in the audit trail and PTB logbook
ABNo
Internal archive block number
This is a number (constant from 1 to 65535) which is used as a label for
one
data record (corresponds to one row) in the archive. For the first time of saving
the block number 1 is issued, then 2 etc. up to 65535. After an overflow
counting starts from "1" again.
Time
Time
Storage time of the data record in the corresponding "archive row".
Time
Date
Storage date of the data record in the corresponding "archive row".
Add
Address of the changed value
Display of the address or the short designation of the changed value
a
Old value
The original valid value before the change.
n
New value
The changed value which is now valid.
St.PL
Status of calibration lock
The status of the calibration lock during the change.
St.ML
Status of manufacturer's lock
The status of the manufacturer's lock during the change.
St.SL
Status of supplier's lock
The status of the supplier's lock during the change.
St.CL
Status of customer's lock
The status of the customer's lock during the change.
Check
Checksum of the data row
Indicates whether the archive row has been correctly saved.
Summary of Contents for DL210
Page 2: ...Data Logger DL210 2 Elster Instromet GmbH ...
Page 9: ...Data Logger DL210 Elster Instromet GmbH 9 ...
Page 10: ...Data Logger DL210 10 Elster Instromet GmbH ...
Page 11: ...Data Logger DL210 Elster Instromet GmbH 11 Part 1 Device description relevant to calibration ...
Page 101: ...Data Logger DL210 Elster Instromet GmbH 101 Part 2 Description of the Initial operation ...
Page 118: ...Data Logger DL210 118 Elster Instromet GmbH Appendix ...