Data Logger DL210
36
Elster-Instromet GmbH
3.1.2 Input 1 set as encoder input
Name
Address Designation / value
Cal.
Access Default DC
Vo
1:240
Original counter, Input 1 (encoder counter)
Yes
-
0
3
V1
1:200
Main counter input 1
Yes
PL
0
3
V1.A
1:203
Adjustable counter, I1
No
S
0
3
Q1
1:210
Flow rate I1
-
-
-
2
L.MI1
12:150 Limit for monitoring I1
No
S
50000
Var.
Md.I1
1:207
Mode I1
Yes
PL
1
4
Md.MI1
12:157 Mode for monitoring I1
No
S
2
4
SC.I1
12:154 Source for monitoring I1
No
S
1:160
Var.
cp.I1
1:253
Cp value I1
Yes
PL
1
3
SNM
1:222
Serial number of the meter on I1
No
S
2
3
Z.Dat
2:01C1 Encoder data
Skip to submenu
11
DS.Ca
1:22E
DS-100 number for Counter V1
No
S
see
Ser.No
3
DS.Cb
1:22F
DS-100 number for Counter V1.A
No
S
see
Ser.No
3
CuNo
1:21A
Customer number for Input I1
No
S
1
3
MP.I1
5:150
Measuring period input I1
Yes
PL
60
3
MP.Re
5:15A
Residual measurement period I1
-
-
-
2
D
V1MP
1:160
Consumption in the current meas. period I1
Yes
-
-
2
D
V1ML
1:161
Consumption in the last meas. period I1
Yes
P
-
2
V1MP
max
3:160
Maximum of meas. period consumption in
current month*
Skip to submenu
11
V1ML
max
3:161
Max. meas. period consumption in last month* Skip to submenu for display of
date / time
11
DB.I1
5:141
Day boundary I1
Yes
P
06:00
3
D
V1.Dy
2:160
Current day counter I1
Yes
-
-
2
D
V1D.L
2:161
Last day counter I1
Yes
-
-
2
V1DB
max
4:160
Max. day counter I1, current month*
Skip to submenu
11
V1D.L
max
4:161
Max. day counter I1, last month*
Skip to submenu
11
ArMo1
1:A30
Month archive I1
Skip to "Month archive I1"
10
ArDy1
13:A30 Day value archive I1
Skip to "Day value archive I1“
10
ArMP1
2:A30
Measurement period archive I1
Skip to "MP archive I1"
10
FrMP1
2:A50
Measurement period archive I1 frozen
No
S
-
6
DC
= Data class (for description see Chap. 2.5.1, page 25.)
P/PL/S/C
=
The displayed value is subject to: "
P
": Calibration lock "
PL
": PTB logbook "
S
":
Supplier's lock "
C
": Customer's lock "-": Value cannot be changed.
*
= for flow recording and high flow display
Summary of Contents for DL210
Page 2: ...Data Logger DL210 2 Elster Instromet GmbH ...
Page 9: ...Data Logger DL210 Elster Instromet GmbH 9 ...
Page 10: ...Data Logger DL210 10 Elster Instromet GmbH ...
Page 11: ...Data Logger DL210 Elster Instromet GmbH 11 Part 1 Device description relevant to calibration ...
Page 101: ...Data Logger DL210 Elster Instromet GmbH 101 Part 2 Description of the Initial operation ...
Page 118: ...Data Logger DL210 118 Elster Instromet GmbH Appendix ...