background image

Motor control unit IMSG-UC-2H • Status 02/08/2011 • Subject to technical changes. Errors excepted. 

8

Connection example with several groups 

For IMSG-UC-2H and/or -4H. 

 

 

Summary of Contents for IMSG-UC-2H

Page 1: ...MSG UC 2H Technical data Elsner Elektronik GmbH Steuerungs und Automatisierungstechnik Herdweg 7 D 75391 Gechingen Germany Phone 49 0 70 56 93 97 0 Fax 49 0 70 56 93 97 20 info elsner elektronik de www elsner elektronik de ...

Page 2: ...rection 1 second motor runtime 240 seconds Connect through clamps Potential free relays Central operation The central input of the IMSG UC 2H allows for example an automatic control unit a timeswitch or a normal unlocked double button Up Down to be connected The central command continuous voltage always has priority over a movement command from the extension inputs LED signals during central contr...

Page 3: ...ond the drive will move in a step by step fashion This allows for example slats to be positioned precisely If a button is held for longer than 1 second the drive moves to its final position switching off after 240 seconds of maximum runtime This is how you set the Standard mode Press the button on the channel to be set for 5 seconds and then additionally the button for longer than 1 second To conf...

Page 4: ...ghten the canvas with For windows you can skip this point Store by again pressing the and buttons for 1 second long at the same time As feedback the drive moves briefly up and down The storage is complete and the IMSG UC 2H is again in normal mode Note As soon as a central command arrives e g because of a wind or rain alarm the Programming mode will be interrupted In this case please carry out the...

Page 5: ...usively for appropriate use Any improper alteration or non observance of the operating instructions will void any warranty or guarantee claim After unpacking the unit shall be checked immediately for any possible mechanical damage The supplier shall be immediately notified in the event of any transport damage The motor control unit must not be used if damaged If it is assumed that danger free oper...

Page 6: ...please note Mixing different control voltages for central and on the spot operation is not permitted for IMSG UC If two motor control units are switched in series behind one another central commands Up and Down are looped through the N connections must be bridged for equipotential bonding Cable length for inputs max 200 m Control with 12V ...

Page 7: ...Motor control unit IMSG UC 2H Status 02 08 2011 Subject to technical changes Errors excepted 7 Control with 230V ...

Page 8: ...Motor control unit IMSG UC 2H Status 02 08 2011 Subject to technical changes Errors excepted 8 Connection example with several groups For IMSG UC 2H and or 4H ...

Reviews: