Motor control unit IMSG-UC-2H • Status 02/08/2011 • Subject to technical changes. Errors excepted. 

5

Ambient temperature:  

Operation -20…+70°C, storage -55…+90°C 

Ambient humidity:  

max. 95% rH, avoid dew

Auxiliary voltage:  

230 V AC, 50 Hz

Inputs:  

• Central (Up/Down) 

• 2 x hand switches (Up/Down buttons) 

Outputs:  

• 2 x Drive 230 V (PE/N/Down/Up), each 4 A 

 

The following standards were used for assessing the product with regard to electro-

magnetic compatibility: 

 

EN 60730-1:2000-11 + A11:2002 

The product was tested by an accredited EMC laboratory in accordance with the 

abovementioned standards. 

 

Installation and commissioning 

Warning, mains voltage! 

National legal regulations are to be observed. 

 

Installation, testing, commissioning and fault repair of the motor control unit may only 

be carried out by a qualified electrician. Shut off the voltage to all cables to be fitted and 

take safety precautions against unintended activation. 

The motor control unit is intended exclusively for appropriate use. Any improper 

alteration or non-observance of the operating instructions will void any warranty or 

guarantee claim. 

 

After unpacking, the unit shall be checked immediately for any possible mechanical 

damage. The supplier shall be immediately notified in the event of any transport 

damage. 

The motor control unit must not be used if  

damaged.  

 

If it is assumed that danger-free operation can no longer be guaranteed, the equipment 

shall be taken out of service and secured against unintended operation. 

The motor control unit may only be operated as a fixed installation, meaning a built-in 

condition and following the completion of all installation and commissioning work, and 

only in the intended environment. 

 

Elsner Elektronik shall not be liable for any changes to norms or standards after the 

publication of these operating instructions. 

 

Installation notes 

Ensure that the unit does not come into contact with water: Even a few drops may 

damage the electronics.  

Ensure that the unit is correctly connected. An incorrect connection can lead to damage 

to the motor control unit or to any electronic device connected to it.  

Summary of Contents for IMSG-UC-2H

Page 1: ...MSG UC 2H Technical data Elsner Elektronik GmbH Steuerungs und Automatisierungstechnik Herdweg 7 D 75391 Gechingen Germany Phone 49 0 70 56 93 97 0 Fax 49 0 70 56 93 97 20 info elsner elektronik de www elsner elektronik de ...

Page 2: ...rection 1 second motor runtime 240 seconds Connect through clamps Potential free relays Central operation The central input of the IMSG UC 2H allows for example an automatic control unit a timeswitch or a normal unlocked double button Up Down to be connected The central command continuous voltage always has priority over a movement command from the extension inputs LED signals during central contr...

Page 3: ...ond the drive will move in a step by step fashion This allows for example slats to be positioned precisely If a button is held for longer than 1 second the drive moves to its final position switching off after 240 seconds of maximum runtime This is how you set the Standard mode Press the button on the channel to be set for 5 seconds and then additionally the button for longer than 1 second To conf...

Page 4: ...ghten the canvas with For windows you can skip this point Store by again pressing the and buttons for 1 second long at the same time As feedback the drive moves briefly up and down The storage is complete and the IMSG UC 2H is again in normal mode Note As soon as a central command arrives e g because of a wind or rain alarm the Programming mode will be interrupted In this case please carry out the...

Page 5: ...usively for appropriate use Any improper alteration or non observance of the operating instructions will void any warranty or guarantee claim After unpacking the unit shall be checked immediately for any possible mechanical damage The supplier shall be immediately notified in the event of any transport damage The motor control unit must not be used if damaged If it is assumed that danger free oper...

Page 6: ...please note Mixing different control voltages for central and on the spot operation is not permitted for IMSG UC If two motor control units are switched in series behind one another central commands Up and Down are looped through the N connections must be bridged for equipotential bonding Cable length for inputs max 200 m Control with 12V ...

Page 7: ...Motor control unit IMSG UC 2H Status 02 08 2011 Subject to technical changes Errors excepted 7 Control with 230V ...

Page 8: ...Motor control unit IMSG UC 2H Status 02 08 2011 Subject to technical changes Errors excepted 8 Connection example with several groups For IMSG UC 2H and or 4H ...

Reviews: