F. MOTOR FIXING
While the motor is disengaged, remove the wire cover and fix the rear bracket with the pin. The
pin will slot into the hole with the threaded side up as shown in no.1. No screw is required to
hold the pin in place. Attach the front bracket to the drive unit with the nut provided as shown
in no.2.
Make sure the iS300 is mounted in a horizontal position, especially in these positions:
1) Gate in “CLOSE” position
2) Gate in “OPEN” position
3) Gate at “45° angle” position
Prior to welding the bracket on the gate leaf( if necessary), cover the gate opener to prevent
damages from sparks.
G. WIRE CONNECTION
To connect the iS300 with the control unit
1 White Motor
(+)
2 Yellow Motor
(-)
Avoid tension in the cable during opening and closing cycles