Complete kit for a pair of swing gates weighing 

up to 200kg per leaf / max. width 1.8m

TO BE READ IN CONJUNCTION WITH THE FULL INSTRUCTION MANUAL

QUICK SETUP GUIDE

Typical gate setup & geometry

Gate motor manual release

Kit wiring diagram

Control panel guide & safety

Summary of Contents for AMICO-S24

Page 1: ... a pair of swing gates weighing up to 200kg per leaf max width 1 8m TO BE READ IN CONJUNCTION WITH THE FULL INSTRUCTION MANUAL QUICK SETUP GUIDE Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety ...

Page 2: ...d4rks Rolling code Transmitter A1824 Motor x2 Amico S24 KIT CONTENTS 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Kit Wiring Diagram 7 Control Panel Quick Start Guide 8 Control Panel Programming Transmitters 9 Control Panel Safety 10 Optional Accessories ...

Page 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate movement during operation Under no circumstances should you attempt to modify the gate automation system Ensure that your gate is serviced at 3 to 12 month intervals dependent on number of openings by...

Page 4: ...le glands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection rating Only a competent service provider should open the enclosure and adjust the settings The photocells are used in pairs one transmitter and one receiver They should be installed between 500 600mm f...

Page 5: ...0 60 720 120 130 110 50 720 Tail joint Bushing Screw M8 x 35 Nut UNI 7474 M8 Bushing Attachment pin Washer Nut M12 Slotted hole Preliminary checks Side hung gate GEOMETRY Tick 1 Check that the gate structure is sturdy enough the hinges work efficiently and that there is no friction between the fixed and moving parts 2 Make sure that measurement C does not exceed the value shown in the reference ta...

Page 6: ...e gate carefully at the same speed as the automatic operator 4 To re engage close the gate and turn the key back to its original position Attempt to manually move the gate to ensure it is fully engaged Basic Maintenance Hints Tips Slide back manual release cover spray locking mechanism with suitable penetrating lubricant Lubricate gate hinges Manually release the gates at least once per month ALWA...

Page 7: ...7 ZL92Z Control Panel AMICO A1824 Gate motor Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm 10 2 TX C NC TX 2 RX TX DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m AF43S Plug in TOP A433N Antenna Cable length RG58 Max 5m Mains Supply 230 V AC Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm ...

Page 8: ... motor cables for motor 2 Connections M2 N2 Leave the gate in the halfway position 9 Setup the Encoder A 3 1 10 The Gate will now perform a close and open cycle 12 Exit the programming using the button 13 Check the gate operation by pulsing across connections 2 7 the gate will close Please refer to the main manual for Changing automatic closing time adjusting encoder settings if required Safety in...

Page 9: ...ill now appear on the screen Press and release a button on a transmitter the number on the screen will increment by one for each button pressed A maximum of 25 individual buttons can be saved Remove transmitter button 1 Press and hold the button for 2 seconds to access programming F1 appears on the display 2 Remove a transmitter button U 2 3 Use the arrow buttons to choose the number associated wi...

Page 10: ... activation from a command device to restart C1 REOPENING DURING CLOSING When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its fully open position again If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence once completed the automation will ...

Page 11: ... blue backlighting RAL7024 Grey colour 806SL 0310 SELR2BDG Flush mounted Bus transponder reader for cards keyfobs and TAG Manchester protocol with blue backlighting RAL7024 Grey colour 001R700 Programming board and access control management when used with transponder Required for 806SL 0300 and 806SL 0310 HARDWIRED KEYPAD SELECTORS 806SL 0280 SELT1BDG Surface mounted 12 button Bus keypad with blue...

Page 12: ...O THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Farm Business Park Castle Donington DE74 2US Tel 0115 921 0430 CAME BPT South Liberta House Maxted Road Maylands Ind Est Hemel Hempstead Herts HP2 7DX Tel 01442 230 800 CAME BPT Ireland Unit 9 The West...