AMICO-S24:
ACCESSORIES
For more kit accessories please contact
Sales
on
0115 9210 430
Code(s)
Description
RADIO KEYPAD SELECTORS
806SL-0170
SELT1W4G - Surface-mounted, 433.92 MHz radio-frequency keypad selector, 12-keys, with blue backlighting. 25 savable
codes and password to access the programming mode. Settable in Rolling Code or Fixed Code mode. RAL7024 Grey colour.
806SL-0180
SELT1W8G - Surface-mounted, 868.35 MHz radio-frequency keypad selector, 12-keys, with blue backlighting. 25 savable
codes and password to access the programming mode. Settable in Rolling Code or Fixed Code mode. RAL7024 Grey colour.
001
AF868
Plug-in 868.35 MHz radio frequency control card.
Required for 806SL-0180.
BLUETOOTH SELECTORS
806SL-0210
SELB1SDG1 - Surface-mounted with blue backlighting, for 15 users. RAL7024 Grey colour.
806SL-0240
SELB1SDG2 - Surface-mounted with blue backlighting, for 50 users. RAL7024 Grey colour.
806SL-0250
SELB1SDG3 - Surface-mounted with blue backlighting, for 250 users. RAL7024 Grey colour.
TRANSPONDER SELECTORS
806SL-0300
SELR1BDG - Surface-mounted Bus transponder reader for cards, keyfobs and TAG (Manchester protocol) with blue
backlighting. RAL7024 Grey colour.
806SL-0310
SELR2BDG - Flush-mounted Bus transponder reader for cards, keyfobs and TAG (Manchester protocol) with blue
backlighting. RAL7024 Grey colour.
001
R700
Programming board and access control management when used with transponder.
Required for 806SL-0300 and 806SL-0310.
HARDWIRED KEYPAD SELECTORS
806SL-0280
SELT1BDG - Surface-mounted 12 button Bus keypad with blue backlighting.
RAL7024 Grey colour.
806SL-0290
SELT2BDG - Flush-mounted 12 button Bus keypad with blue backlighting.
RAL7024 Grey colour.
001
R800
Control board for programming and access-control management via keypad selectors.
Required for 806SL-0280 and 806SL-0290.
TOP - ROLLING CODE
8K06TS-001
TOPD4RXM - 6 packaged dual frequency 4 button rolling code transmitters.
4,294,967,896 combinations.
PHOTOCELLS
Surface mounted. Synchronised beam, multiple pairs of photocells can be applied to the same system,
even at double height and/or close to each other - with no interference issues (cross talk).
001
DIR10
Pair of 12 - 24 V AC - DC outdoor photocells - range 10m.
001
DIR20
Pair of 12 - 24 V AC - DC outdoor photocells - range 20m.
001
DIR30
Pair of 12 - 24 V AC - DC outdoor photocells - range 30m.
PHOTOCELL column
001
DIRL
Natural finish aluminium post. H = 500mm
001
DIRLN
Black anodised aluminium post. H = 500mm
001
DIRCG
Silver RAL9006, PVC post. H = 500mm
ZL92Z:
SAFETY
FUNCTIONS > CX Input, CY Input
SAFETY INPUTS
If during the reverse motion a diff erent safety is triggered the automation will perform the appropriate action for the new triggered
safety, should multiple safeties be triggered at the same time the automation will be halted at its current position.
SENSITIVE EDGES
C7
REOPENING DURING CLOSING
• When the automation is in its closing cycle and the safety circuit is triggered the automation will reverse its motion until it reaches its fully open
position again.
• If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the
automation will start the closing cycle again.
• If the auto closing option is not enabled the automation will return to the fully open position awaiting another activation from a command device.
C8
RECLOSING DURING OPENING
• When the automation is in its opening cycle and the safety circuit is triggered the automation will reverse its motion until it reaches its fully
closed position again.
• Once the automation has reached the fully closed position it will require another activation from a command device to restart.
The above sequence will be attempted 3 times before the automation is halted, the automation will then
require activation from a command device to restart.
C1
REOPENING DURING CLOSING
• When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its
fully open position again.
• If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the
automation will start the closing cycle again.
• If the auto closing option is not enabled the automation will return to the fully open position awaiting another activation from a command device.
C2
RECLOSING DURING OPENING
• When the automation is in its opening cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its
fully closed position again.
• Once the automation has reached the fully closed position it will require another activation from a command device to restart.
C3
PARTIAL STOP
• When the automation is in its opening cycle and the safety circuit is triggered the automation will stop.
• If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the
automation will start closing the device.
C4
OBSTRUCTION WAIT
• When the automation is in either its opening or closing cycle and the safety circuit is triggered the automation will stop.
• Once the safety is no longer triggered the automation will carry on the cycle it was performing at the time it was interrupted.