Cleaning and servicing
138
13.4
CLEANING INTERVALS
Cleaning intervals can be set and called up as a function for regular cleaning.
Fig. 75:
Setting and activating cleaning interval
Item
Function
Default value
Setting range
1
Parameter = 21 in
Settings/Service, level 2
2
Cleaning interval
ON/OFF
3
Interval
25 h
5 h–100 h
4
Manual "Reset" in Settings/Service, level 2
Tab. 35:
Elements of the
Cleaning interval setting
screen