Troubleshooting
164
15.2
FAULT MESSAGES AND REMEDIES
Code
Display
Possible cause
Troubleshooting
600
604
Cleaner is empty (15%).
Cleaner is empty (30%).
Replace the cleaner .
601
605
Rinsing agent is empty
(15%).
Rinsing agent is empty
(30%).
Replace the rinsing
agent .
602
Water filter is empty.
Replace the water
filter.
Water pressure is too
low.
Contact an Eloma
service partner.
001
Cooking/baking
chamber door is open.
Close the
cooking/baking
chamber door.
318
Not enough water to
generate steam.
Check the water
connection.
551
The USB stick is not
inserted.
Connect the USB stick.
550
Software error
Reset the device.
Contact an Eloma
service partner.
111
Cooking chamber
probe 1 is faulty.
Contact an Eloma
service partner.
112
Cooking chamber
probe 2 is faulty.
Contact an Eloma
service partner.
113-116
The core temperature
probe is faulty.
Contact an Eloma
service partner.
The combi steamer can
only be operated with
restrictions.
117/127
Probe for steam
damping is faulty.
Contact an Eloma
service partner.
The combi steamer can no
longer be operated.
Summary of Contents for GENIUS MT
Page 169: ...Appendix 169 Ende der Liste für Textmar ke Inhalt4 ...
Page 170: ...Appendix 170 ...
Page 171: ...Appendix 171 ...