Not-Halt Taster/Emergency-Stop push-button/Bouton-poussoir d'arrêt d'urgence/
Pulsante di arresto d'emergenza/Pulsador de paro de emergencia
Art.-Nr./Art. No./Réf./N° art/N° art.: 9010019B01M
Version/Version/Version/Versione/Versión: 1.0
Datum/Date/Date/Data/Fecha: 15.08.2016 3/13
Emergency-Stop push-button NHT... /
Contact elements KE...
Translation of the original operating instructions
Table of contents
About these operating instructions .......................................................3
Designated use.....................................................................................3
Area of application................................................................................3
Warning against misuse .......................................................................3
Technical specifications........................................................................4
Installation and connection of the built-in version.................................4
Installation and connection of the mounted version .............................4
Check before commissioning ...............................................................4
Maintenance and inspection.................................................................4
Further operating instructions...............................................................4
Declaration of conformity ..............................................................................14
1
About these operating instructions
The following standard models are described:
NHT...
KE...
The person installing the Emergency-Stop push-button must be provided with
the operating instructions.
The operating instructions must be kept in a legible condition and in an acces-
sible location.
Meaning of the symbols used:
2
Designated use
The Emergency-stop push-buttons are electromechanical switches designed
to protect persons on or near machinery. They are used to switch off/shut
down machines and systems to avoid or minimise emerging or existing haz-
ards to persons or damage to the machine or workpieces.
3
Safety instructions
The person installing the Emergency-Stop push-button must be provided with
the operating instructions. Read these operating instructions carefully and re-
tain for future reference.
4
Area of application
The national and international legislation applies to the use and installation of
the Emergency-stop push-button as well as for commissioning and recurrent
technical inspections, in particular:
2006/42/EC Machinery Directive
the safety regulations
the accident prevention regulations and safety rules
Manufacturers and users of the machine on which the safety equipment is
used are responsible for coordinating and complying with all applicable safety
regulations in collaboration with the relevant authorities.
Designated use includes the compliance with all relevant requirements for in-
stallation and operation, in particular:
EN ISO 13849-1
DIN EN 60204-1
EN ISO 13850
Designated use also includes regular inspection of the safety equipment (see
point 7) by experts.
5
Warning against misuse
6
Exclusion of liability
No liability shall be accepted for any damage or operational faults caused by a
failure to observe these operating instructions. All further liability of the manufac-
turer is excluded in the case of damage caused by the use of replacement and
accessory parts that have not been authorized by the manufacturer.
No unauthorized repairs, conversions or modifications are permitted for reasons
of safety and the manufacturer shall not be liable for any resulting damage.
7
Function
The contact element is actuated by means of the button. The contact elements
are also available with failure protection to maintain safety in the event of a volt-
age drop of the contact element of the push-button. This opens a contact when
the contact element is disconnected from the button. The failure protection thus
detects a fault and triggers the emergency stop function.
Please observe the wiring diagram on the contact element.
Release
- Twist release:
turning clockwise/counter-clockwise
- Key release:
only NHT04S
Product description
The Emergency-Stop push-button consists of a push-button and a contact el-
ement with up to five functions.
The Emergency-Stop push-buttons are available as a built-in version and as
a mounted version with an enclosure.
Warning
Failure to observe this warning may result in faults or
malfunctions.
Failure to observe this warning may result in personal injury
and/or damage to the machine.
Information
Indicates available accessories and useful additional
information.
Danger
- Before beginning installation!
Disconnect system and device from power supply!
- Emergency-Stop push-buttons fulfil a personal protection func-
tion.
Incorrect installation or manipulations may lead to serious personal
injuries!
- Emergency-Stop push-buttons must not be circumvented,
removed or otherwise put out of action!
- The switching process may only be triggered by suitable actua-
tors which are safety connected to the contact element!
- Use suitable connectors for the contact elements.
- Incorrect installation or manipulations may lead to damage to
the machine and workpiece!
GB
Danger
- The Emergency-Stop function must not be used as a substitute
for protective measures or other safety functions, but should be
designed as an additional protection measure.
- The Emergency-Stop function must not impair the effectiveness
of safety equipment or of equipment with other safety functions.
- The designer must ensure with a risk analysis that the emergen-
cy stop complies with the required safety category in combina-
tion with the control.
- When using emergency stops with key release the key must
only be inserted during the releasing procedure.
- In case of incorrect or unintended use or manipulation, the use
of the Emergency-Stop push-button does not exclude risks to
persons or damage to the machine or system components.
Please also observe the relevant information stipulated in
EN ISO 14119.
- An exceeding the electrical specifications of the Emergency-
Stop push-button (e.g. in the event of incorrect wiring or short-
circuits) may cause irreparable damage to the system.