C-92
I n t e l l i T o u c h / S e c u r e T o u c h G u i d e
To avoid confusion in selecting suitable gasket materials, elastomers that cannot
be crosslinked using sulfur are recommended. These elastomers include
silicones, polyurethanes and saturated polyolefins, which are crosslinked using
high energy irradiation, peroxide or other chemical crosslinking reactions.
Some examples of vendors of these materials include Rogers Corporation
(www.rogers-corp.com) for silicone gasket materials (BISCO Cellular
Silicones) and polyurethane gaskets (PORON). Voltek, Division of Sekisui
America Corporation (www.voltek.com) supplies irradiation and chemically
crosslinked polyethylene foams (Volara and Minicel).
Optical
Light Transmission
Light Transmission testing is in accordance with ASTM D 1003.
HL Products: 80% +/-5% at 550 nm wavelength (visible light spectrum).
Visual Resolution
All measurements made using USAF 1951 Resolution Chart, under 30X
magnification, with test unit located approximately 1.5 inch (38 mm) from
surface of resolution chart.
Antiglare surface: 6:1 minimum
Haze:
Haze testing is in accordance with ASTM D 1003.
Antiglare surface: Less than 15%
Gloss
Gloss testing is in accordance with ASTM D 2457.
Antiglare surface: 90
±
20 gloss units tested on a hard-coated front surface.
Summary of Contents for AccuTouch 821615-000
Page 3: ...4...
Page 5: ...12...
Page 9: ...8...
Page 15: ...1 16 E l o E n t u i t i v e T o u c h m o n i t o r...
Page 55: ...4 60 E l o E n t u i t i v e T o u c h m o n i t o r...
Page 75: ...A 80 I n t e l l i T o u c h S e c u r e T o u c h G u i d e...
Page 78: ...B 83 2210 Serial Controller Figure B 2 E271 2210 Serial Controller...
Page 83: ...B 88 I n t e l l i T o u c h S e c u r e T o u c h G u i d e...
Page 92: ...C 97...
Page 93: ...C 98 I n t e l l i T o u c h S e c u r e T o u c h G u i d e...