14
Replacing the Needle Bar Rest
To remove:
1. Remove spool stand, head cover (right), right cover and
left cover.
2. Disconnect the thread catcher unit connector.
Remove the two setscrews (A) and setscrew (B). Re-
move the thread catcher unit.
3. Loosen the setscrew (C). Pull the needle bar main shaft
up and remove it from the machine.
4. Loosen the setscrew (D) and remove the needle bar
rest from the needle bar main shaft.
To attach:
5. Reverse the procedure above. Attach the needle bar
main shaft so its bottom end is level with the bottom
surface of the head frame.
6. Adjust the needle height after the replacement.
Setscrews (A)
Connecter
Setscrew (B)
Needle bar main shaft
Setscrew (C)
Needle bar rest
Setscrew (D)
Bottom of the head frame