PECIFICATION

 

 

 

Sound Output 

 

105dB(A) peak @ 1m Modulated tone. 

Power Supply 

 

9.0 – 15.0Vdc, 13.8Vdc nominal 

Current Consumption 

 

20 mA max (quiescent)  

Sounding   

 

175 mA max 

Strobing   

 

140 mA max. 

Cut-off Timer  

 

Selectable 

[5s, 5, 10, 15]

 minutes or no cut-off 

Battery 

 

 

6V 300mAh NiMH - Battery recharge in less than 24 hours  
(Following 2 x 15 minute sounding) 

Strobe 

 

 

LED, 1Hz flash rate reducing to 0.5Hz after 15 minutes 

Tamper 

 

 

Cover and Rear 

Tamper Output 

 

Volt free contact, maximum 16Ω resistance 
Max 100mA current rating 

Sound Trigger Input 

 

R- < 3.5Vdc = sound ON R- > 8.5Vdc = sound OFF 

   

 

 

12mA max 

Strobe Trigger Input 

 

ST- < 6.5Vdc = strobe flash ON ST- > 6.6Vdc = strobe OFF 

   

 

 

5mA max 

Fixings 

 

 

No 10 (M5) self tapping screws (4-off) 

Cover Material 

 

Polycarbonate 

Backplate Material 

 

Polycarbonate  

Lens Material 

 

Polycarbonate 

Operating Temperature  

- 25

o

C to +60

o

Storage Temperature 

 

- 25

o

C to +70

o

 

C

OMPLIANCE

 

 

 

This product meets the essential requirements of the following EU Directives: 

EMC:  

2004/108/EC 

RoHS: 

2002/95/EC 

WEEE: 

2002/96/EC 

Battery: 

2006/66/EC 

 

EN50131-4:2009 

Security Grade 3 

 

Environmental Class IV 

 

This product is suitable for use in systems designed to comply with PD6662:2010 at: 

Grade 3 and Environmental Class IV. 

 
 
 

 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly.

 

 

 

 

             

 

 

          

Summary of Contents for VERTEC-3000-G3

Page 1: ...h fault output Remote test input facility Selectable sound auto cut off timer no cut off 5s for test 3 10 15 minutes Full SAB using internal battery Twin Comfort LEDs selectable on off alternate flash...

Page 2: ...CTIONAL INFORMATION Tamper Circuit for Single or Multiple Cascade Installations For a single siren installation link TS to H and connect TR to the control panel Tamper return input In cascade installa...

Page 3: ...pproximately 1Hz SAB Mode In SAB mode the sounder can draw current from both the control panel and the battery The siren will self activate if either of the tampers are activated In SCB mode the sound...

Page 4: ...strobe Trigger and Supply BAT Negative battery connection Connect black battery lead after applying power Panel First Only unit Last unit Furthest from panel 0V Strobe Trigger Fault i p Fault i p 12V...

Page 5: ...rol panel bell and strobe outputs are switched off Remove cover and check sounder operates due to top tamper 4 If a Tamper Return connection is made to the control panel check that the panel detects a...

Page 6: ...rectly connected FAULT FINDING Symptom Fault Action Sounder activated in non alarm condition and tamper at panel Cover not closed correctly Check cover closed and screw secure Rear tamper insert disen...

Page 7: ...s DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Directives 2002 96 EC Waste Electrical and Electronic Equipment WEEE and 2006 66 CE Battery At the end of life the produc...

Page 8: ...urrent rating Sound Trigger Input R 3 5Vdc sound ON R 8 5Vdc sound OFF 12mA max Strobe Trigger Input ST 6 5Vdc strobe flash ON ST 6 6Vdc strobe OFF 5mA max Fixings No 10 M5 self tapping screws 4 off C...