Technical Support Line +44 (0)23 9269 6638 (Option 3) 

PAK200218 Iss 05B  Oct 2012 

©2012 ELMDENE INTERNATIONAL LTD 

 

 

C

ONNECTIONS

 

 

 

ENG 

Optional engineer input for quiet operation 
during installation/ maintenance. 

 

HEALTHY 
(x2) 

Volts free siren Healthy/Fault output - normally closed (Healthy)

 

H+ 

Permanent Positive Hold off Supply

 

TS 

Tamper select. Connect to H- for single unit or last in line. Connect 
to TR of next unit for multiple unit installation (see Figure 4.0)

 

H- 

Permanent Negative Hold off Supply

 

TR 

Tamper return connection to control panel

 

R-

 

Negative Siren Trigger 

BAT+

 

Positive connection to battery 

ST- 

Negative strobe Trigger and Supply 

BAT-

 

Negative battery connection. Connect black battery lead after 
applying power. 

 
 
 

 

 
 
Panel 

First /Only unit 

Last unit 

 

(Furthest from panel) 

 

 

 

 

0V Strobe 

Trigger 

Fault i/p 

Fault i/p 

+12V 

0V 

Tamper 

 Return 

0V Siren 

Trigger 

Prog o/p 

H+ 

H- 

TS 

TR 

R- 

ST- 

ENG 

Healthy 

Healthy 

H+ 

H- 

TS 

TR 

R- 

ST- 

ENG 

Healthy 

Healthy 

Figure 3: Multiple cascade siren connections 
 

 

 

0V Strobe 

Trigger 

Fault i/p 

Fault i/p 

H+ 

H- 

TS 

TR 

+12V 

0V 

Tamper 

Return 

0V Siren 

Trigger 

Prog o/p 

R- 

ST- 

ENG 

Healthy 

Healthy 

Figure 2: Single siren connections 

Note 1: 
Where the siren Trigger is not pulled up to > +8.5V by the 
control panel when in standby mode, or is operated  via 
volt free contacts, it will be necessary to fit a pull up 
resistor (1k0) as shown, at the control panel to enable 
monitoring of the Trigger connection. 

 

 

 

 

             

 

 

          

See Note 1 

See Note 1 

Summary of Contents for VERTEC-3000-G3

Page 1: ...h fault output Remote test input facility Selectable sound auto cut off timer no cut off 5s for test 3 10 15 minutes Full SAB using internal battery Twin Comfort LEDs selectable on off alternate flash...

Page 2: ...CTIONAL INFORMATION Tamper Circuit for Single or Multiple Cascade Installations For a single siren installation link TS to H and connect TR to the control panel Tamper return input In cascade installa...

Page 3: ...pproximately 1Hz SAB Mode In SAB mode the sounder can draw current from both the control panel and the battery The siren will self activate if either of the tampers are activated In SCB mode the sound...

Page 4: ...strobe Trigger and Supply BAT Negative battery connection Connect black battery lead after applying power Panel First Only unit Last unit Furthest from panel 0V Strobe Trigger Fault i p Fault i p 12V...

Page 5: ...rol panel bell and strobe outputs are switched off Remove cover and check sounder operates due to top tamper 4 If a Tamper Return connection is made to the control panel check that the panel detects a...

Page 6: ...rectly connected FAULT FINDING Symptom Fault Action Sounder activated in non alarm condition and tamper at panel Cover not closed correctly Check cover closed and screw secure Rear tamper insert disen...

Page 7: ...s DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Directives 2002 96 EC Waste Electrical and Electronic Equipment WEEE and 2006 66 CE Battery At the end of life the produc...

Page 8: ...urrent rating Sound Trigger Input R 3 5Vdc sound ON R 8 5Vdc sound OFF 12mA max Strobe Trigger Input ST 6 5Vdc strobe flash ON ST 6 6Vdc strobe OFF 5mA max Fixings No 10 M5 self tapping screws 4 off C...