1.

 

Remove cover, undo module fixing screw and swing electronics module away from backplate. Module will self support 
when pivots are pushed back in their pivot slots 

2.

 

Offer backplate to desired position on mounting surface and drill holes to match chosen fixing centres and rear tamper 
insert. A minimum of three fixings should be used. 

3.

 

Pierce cable grommet (supplied) to match diameter of control panel cable. Grommet must be used to prevent water 
ingress via cable. 

4.

 

Fix grommet to backplate and pass control cable through grommet. 

5.

 

Fix backplate to mounting surface using appropriate fixings for the mounting 
surface. 

6.

 

Fix tamper insert to mounting surface using an appropriate fixing for the 
mounting surface

 

7.

 

Swing electronics module onto backplate and verify that rear tamper pin is 
depressed when in contact with the tamper insert. 

8.

 

Set the required Cut-off Timer (J1 & J6), LED option (J2 & J7), Tone options 
(J4 & J5) and SAB/SCB option (J8). 

9.

 

Connect ENG input to H+ or to a switched output of control panel set high. 

10.

 

Make remaining connections to control panel in the following order: 
sounder activate, strobe activate, tamper return, negative power supply, 
positive supply. 

11.

 

Connect the black battery lead to BAT-. 

12.

 

Disconnect ENG from H+. 

13.

 

Lower inner cover and fix using self tapping screw supplied. 

14.

 

Replace cover temporarily. Sounder should stop when cover completely replaced. 

 

T

ESTING 

 

 

 

1.

 

Activate bell or ring output from control panel. Check sounder activates. 

2.

 

Activate strobe output from control panel. Check strobe flashes. 

3.

 

Ensure control panel bell and strobe outputs are switched off. Remove cover and check sounder operates due to top 
tamper. 

4.

 

If a Tamper Return connection is made to the control panel, check that the panel detects a tamper active condition. 

5.

 

Temporarily replace cover. Check that sounder switches off. Check that the tamper active condition has cleared at the 
control panel. 

6.

 

Unfasten inner cover fixing screw so that module sits away from wall mounting and rear tamper is activated. Temporarily 
replace cover and check that sounder activates. Check that a tamper active condition is detected at the control panel. 

7.

 

Push cover and module into its fully seated position closing the rear tamper pin. Check that sounder switches off and that 
the tamper condition is cleared at the control panel. 

8.

 

Securely fasten inner cover retaining screw. 

9.

 

ve sounder power supply connection at control panel. Check sounder activates and a tamper active condition is 
detected at the control panel. 

10.

 

Rve sounder power supply. Check tamper active condition is cleared at control panel. 

11.

 

Remove -ve sounder power supply connection at control panel. Check sounder activates and a tamper active condition is 
detected at the control panel. 

12.

 

Replace -ve sounder power supply. Check tamper active condition is cleared at control panel. 

13. 

Disconnect R- at control panel, check that the siren activates

 

14.

 

Check correct operation of comfort LEDS. 

15.

 

Fasten cover to backplate using two fixing screws supplied. Fit screw covers. 

16.

 

Testing complete. 

   

M

AINTENANCE

 

 

       

1.

 

The sounder should be tested for correct operation on a periodic basis. A minimum of one check every 12 months is 
recommended. The following features should be verified on each maintenance visit: 

2.

 

Correct operation of sounder and strobe from control panel signals 

3.

 

Correct operation of cover and rear tampers. 

 
 

 

 

 

             

 

 

          

 

Figure 4: Tamper insert 

mounting 

Summary of Contents for VERTEC-3000-G3

Page 1: ...h fault output Remote test input facility Selectable sound auto cut off timer no cut off 5s for test 3 10 15 minutes Full SAB using internal battery Twin Comfort LEDs selectable on off alternate flash...

Page 2: ...CTIONAL INFORMATION Tamper Circuit for Single or Multiple Cascade Installations For a single siren installation link TS to H and connect TR to the control panel Tamper return input In cascade installa...

Page 3: ...pproximately 1Hz SAB Mode In SAB mode the sounder can draw current from both the control panel and the battery The siren will self activate if either of the tampers are activated In SCB mode the sound...

Page 4: ...strobe Trigger and Supply BAT Negative battery connection Connect black battery lead after applying power Panel First Only unit Last unit Furthest from panel 0V Strobe Trigger Fault i p Fault i p 12V...

Page 5: ...rol panel bell and strobe outputs are switched off Remove cover and check sounder operates due to top tamper 4 If a Tamper Return connection is made to the control panel check that the panel detects a...

Page 6: ...rectly connected FAULT FINDING Symptom Fault Action Sounder activated in non alarm condition and tamper at panel Cover not closed correctly Check cover closed and screw secure Rear tamper insert disen...

Page 7: ...s DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Directives 2002 96 EC Waste Electrical and Electronic Equipment WEEE and 2006 66 CE Battery At the end of life the produc...

Page 8: ...urrent rating Sound Trigger Input R 3 5Vdc sound ON R 8 5Vdc sound OFF 12mA max Strobe Trigger Input ST 6 5Vdc strobe flash ON ST 6 6Vdc strobe OFF 5mA max Fixings No 10 M5 self tapping screws 4 off C...

Reviews: