background image

 
 
 
 
 
 
 
 
 
 

INT600/INT600S Internal Sounder 

with Hi/Lo Feature

 

Note: This unit NOT suitable for external installation 

EN50131-4: 2009 

INT600 

INT600S 

Power Source 

Remote 

Self Powered 

Security Grade 

Environmental Class 

II 

II 

 

F

EATURES

 

 

 

-

 

108dB(A) siren output 

-

 

Independent low volume E/E, Keypad output 

-

 

12V dc voltage operation 

-

 

Polycarbonate cover and backplate 

-

 

2 way tamper protection: cover, rear 

-

 

Volt Free Tamper Connection  

-

 

Hold-off supply failure detection 

-

 

Selectable sound auto cut-off timer 

-

 

Full SAB using internal battery (INT600S) 

O

PERATION

 

 

 

The 

INT600

 sounder is used for notification of an alarm condition and entry/exit tone as generated within 

an intruder, hold-up or other alarm system. In response to appropriate commands from the control panel, 
the 

INT600

 will emit a high intensity sound for alarm and an adjustable low level tone for 

entry/exit/keypad. 
 
The 

INT600

 will detect any attempt to gain unauthorised access to the sounder by removal of the cover, or 

any attempt to remove it away from its mounting surface. This will generate a tamper signal which is 
normally fed back to the alarm control panel 
 
The 

INT600

 is classified as an internal remote powered sounder and is powered via an external power 

source.  
The 

INT600S 

is classified as an internal self powered sounder and has an on-board battery which is 

recharged via the external power source. This battery is used to operate the sounder if the external power 
to the sounder is removed.  
 

F

UNCTIONAL 

I

NFORMATION

 

 

 

T

AMPER 

C

IRCUIT

 

Volt free tamper terminals ‘TS & TR’ open when front or rear tamper switch is open, or on loss of H+ or H-. 

 

              

 

Elmdene International Ltd

 

 

Tel:  +44(0)23 9269 6638 

3 Keel Close, Interchange Park, 

 

Fax:  +44(0)23 9266 0483 

Portsmouth, Hampshire, PO3 5QD, UK 

Web:   

www.elmdene.co.uk

 

Summary of Contents for INT600

Page 1: ... intensity sound for alarm and an adjustable low level tone for entry exit keypad The INT600 will detect any attempt to gain unauthorised access to the sounder by removal of the cover or any attempt to remove it away from its mounting surface This will generate a tamper signal which is normally fed back to the alarm control panel The INT600 is classified as an internal remote powered sounder and i...

Page 2: ...ent negative hold off supply TR Volt free tamper connection TS Volt free tamper connection BT SAB Battery negative BT SAB Battery positive COMMISSIONING 1 Remove cover 2 Offer backplate to desired position on mounting surface and drill holes to match chosen fixing centres 3 Fix backplate to mounting surface using appropriate fixings for the mounting surface 4 Set the required Cut off Timer using J...

Page 3: ...supplied MAINTENANCE This sounder should be tested for correct operation on a periodic basis A minimum of one check every 12 months is recommended The following features should be verified on each maintenance visit 1 Correct operation of sounder from control panel signals 2 Correct operation of cover and rear tampers 3 Remove the ve power supply from the control panel and check internal battery vo...

Page 4: ...Package used batteries safely for onward transport to your supplier collection point or disposal facility Caution risk of fire or explosion if bare battery wires are allowed to touch See Specification for battery type information The battery is marked with the crossed out wheelie bin symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For more information see www recycl...

Reviews: