background image

2

 

 

 

 

Technical Support: +44(0)23 9269 6638 (option 3) 

  PAK200035_07A   Oct 2014                        ©2014 ELMDENE INTERNATIONAL LTD  

 

 
 

 

 

JP1: Cut-off timer for alarm (R-) 

 

Link = no cut-off (default) 

 

No link = sounder cut-off after 15 minutes 

 

VR1: Volume control for entry/exit/keypad low level tone (M-) 
 

 
 

 

                                                                                                 Figure 1. Connections and Timer Selection Jumper 

 

With the cut-off timer link NOT fitted, the 

INT600(S)

 sounder will automatically stop sounding after 15 

minutes, irrespective of the status of the sound trigger (R-) input.  

SAB

 

M

ODE 

(INT600S

 

O

NLY

 

 

SAB mode is enabled if the internal battery is connected, the unit will then self-activate if the tamper is 
activated or the supply cut. 

 

C

ONNECTIONS

 

 

 

R-

 

Negative siren trigger for alarm. Apply 0V to activate sounder 

M-

 

Negative low volume trigger for entry/exit/keypad. Apply 0V to activate. 

ST-

 

Not applicable. 

H+

 

Permanent positive hold-off supply, +12Vdc nominal 

H-

 

Permanent negative hold-off supply 

TR 

Volt free tamper connection

 

TS

 

Volt free tamper connection 

BT-

 

SAB Battery negative

  

BT+

  SAB Battery positive

 

 

C

OMMISSIONING

 

 

 

1) 

Remove cover. 

2) 

Offer backplate to desired position on 
mounting surface and drill holes to match 
chosen fixing centres. 

3) 

Fix backplate to mounting surface using 
appropriate fixings for the mounting surface. 

 

4) 

Set the required Cut-off Timer using JP1. 

5) 

Loop the connection cable three times through the supplied ferrite as shown. 

6) 

C12V dc and 0V supply from the control panel to H+ and H- respectively. 

7) 

Connect R- to Ring or Bell output of the control panel.

 

8) 

Connect TS to H- and TR to tamper return of panel for 0V tamper return, or use TS & TR as volt free 
contacts without link between TS & H-.

 

9) 

If low output tone facility is used, connect M- to control panel ‘keypad follow’ or a programmable 
output. 

10) 

For SAB facility (INT600S only) connect the battery wires to BT+ and BT-, ensuring correct polarity. 

 

NOTE: The unit will sound until the cover is replaced. 

S

OUND 

C

UT

-O

FF 

T

IMER

 

 

V

R

1

 

ST-

  M-  R-   H+   H-   TR  TS  BT+  BT- 

JP1 

 

Summary of Contents for INT600

Page 1: ... intensity sound for alarm and an adjustable low level tone for entry exit keypad The INT600 will detect any attempt to gain unauthorised access to the sounder by removal of the cover or any attempt to remove it away from its mounting surface This will generate a tamper signal which is normally fed back to the alarm control panel The INT600 is classified as an internal remote powered sounder and i...

Page 2: ...ent negative hold off supply TR Volt free tamper connection TS Volt free tamper connection BT SAB Battery negative BT SAB Battery positive COMMISSIONING 1 Remove cover 2 Offer backplate to desired position on mounting surface and drill holes to match chosen fixing centres 3 Fix backplate to mounting surface using appropriate fixings for the mounting surface 4 Set the required Cut off Timer using J...

Page 3: ...supplied MAINTENANCE This sounder should be tested for correct operation on a periodic basis A minimum of one check every 12 months is recommended The following features should be verified on each maintenance visit 1 Correct operation of sounder from control panel signals 2 Correct operation of cover and rear tampers 3 Remove the ve power supply from the control panel and check internal battery vo...

Page 4: ...Package used batteries safely for onward transport to your supplier collection point or disposal facility Caution risk of fire or explosion if bare battery wires are allowed to touch See Specification for battery type information The battery is marked with the crossed out wheelie bin symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For more information see www recycl...

Reviews: