60/68
MWA60R/T
14.0 DISQUALIFICATION (Important warning!)
In order to prevent and notify misalignments caused either when the system is off or by obstacles placed in between
the barrier actuation beam,
it is essential that the
disqualification output (terminal “D”) shall be connected.
Output “D”
provides a transistorized negative (max. 50 mA) that will no longer be available when the signal level falls
below a minimum level for more than 30 seconds.
15.0 OPTIONAL BRACKETS
The optional brackets (
SP20/MWA
and
SP50/MWA
models) can be used for wall
mounting.
SP20/MWA
SP50/MWA
SP130/MWA
(Buried or cemented).
Note:
secure the base to the pole by means
of two M8x30 bolts and 2 M8 nuts.
SP120/MWA
Floor mounting by means
of dowels
The optional brackets (
SP120/MWA
and
SP130/MWA
models) can be used for floor mounting.