background image

DS80MM1E-001C 

 

 

 

T

T

e

e

s

s

t

t

 

 

m

m

o

o

d

d

e

e

 

 

The contact can be set to Test mode for 3 minutes by pressing the Test button on the front cover once. The LED lights up 

whenever the contact is activated in Test mode. Whenever the Test button is pressed, the contact transmits a signal to 
the  control  unit  to  test  the  wireless  range  and  re-activates  Test  mode  again  for  three  minutes.

 

Test  mode  will  end 

automatically after 3 minutes and will return to normal operating mode.

 

 

 

L

L

e

e

a

a

r

r

n

n

i

i

n

n

g

g

 

 

p

p

r

r

o

o

c

c

e

e

d

d

u

u

r

r

e

e

 

 

Step 1: Remove the battery insulation. 

Step 2: Start the learning function on the control unit; see the control unit manual for more information. 
Step 3: Press the Test button on the contact to send a signal to the control unit. 

Step 4: If the control unit receives the signal correctly will respond by emitting beeps. Refer to the manual of the control 

unit to complete the learning process.  

Step 5: After the contact has been learnt, set the control unit to "Walk Test" mode, by holding the contact in the desired 

position and press the Test button to check that it is within the wireless range of the control unit.  
Step 6: After having checked the correct position of contact, proceed with the installation. 

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

Step 1: 

Install the contact using one of the methods described below.

 

Step 2: 

Install the magnet on the part with the most movement (such as a door) using the screws supplied (double-

sided tape is provided only if drilling is not possible).

 

Align the magnet with the indicators of the contact. 

If necessary, use the magnet spacer to correctly align it with the indicators. 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

 

With the door closed, the magnet must be at a distance of less than 15 mm from the detector. 

 

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

m

m

e

e

t

t

h

h

o

o

d

d

 

 

There are two ways to install the contact: with double-sided adhesive tape or with screws. 

 

Installation with double-sided adhesive tape (exceptional cases only) 

I. 

Clean the surface using a suitable degreaser. 

II. 

According  to  the  installation  side,  remove  the  protective  film  from  one  of  the 

sides  of  the  double-sided  tape  and  make  it  adhere  firmly  to  the  back  of  the 

device. 

III. 

Remove  the other  protective  film  and  make  it  adhere  tightly  to  the contact  in 

the desired position. 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

 

Do not use the installation method with double-sided adhesive tape on surfaces with 

peeling or cracked paint or on uneven surfaces. 

 

Install  the  contact  on  the  part  which  does  not  move  (as  the  frame  of  a  door  or  a 

window)  and  install  the  magnet  on  the  moving  object  (such  as  the  door  or  the 

window). Carefully check that the rubber cap mounted on the tamper switch is still in 

place. 

 

 

Installation with screws 

The base is provided with provisions where the plastic is thinner to allow installation.  
To fit the contact:  

I. 

Remove the cover by undoing the retaining screws. 

II. 

Break the areas provided on the base. 

III. 

Using a template for the holes, make the holes in the wall.  

IV. 

Insert the anchor bolts if the device is fixed to plaster or bricks.  

V. 

Screw the base into the anchor bolts.  

VI. 

Secure the cover to the base and tighten the cover fixing screws. Carefully check 

that the rubber cap mounted on the tamper switch is still in place. 

 

 

 

 

T

T

e

e

c

c

h

h

n

n

i

i

c

c

a

a

l

l

 

 

s

s

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

 

 

 

Power supply: 1 3V CR2 lithium battery 

 

Battery life: 10 years (typical value, can vary according to use) 

 

Two-way radio frequency 868.6375 MHz 

 

Working temperature range -10°C to +45°C 

 

Dimensions: 85 mm x 25 mm x 20 mm 

 

Weight: 100g  

 

Compliant with EN 50131 Grade 2, Class

 

 

 

 

SIMPLIFIED EU DECLARATION OF CONFORMITY 

The manufacturer, URMET S.p.A., hereby declares that the wireless device: DC600 10A DC600 MINI MAGNETIC CONTACT 

complies with Directive 2014/53/EU. The complete EU Declaration of Conformity can be downloaded from the following Internet 

address:

 

www.elkron.com

 

 

 

Door / 

Window 

Provisions 

Frame 

Summary of Contents for DC600

Page 1: ...netic contact Weißer oder brauner Mini Magnetkontakt Contact magnétique mini blanc ou marron Manuale d uso installazione e programmazione Installation programming and functions manual Installations programmier und gebrauchsanleitun Notice di installation programmation et utilization I EN DE FR ...

Page 2: ...nete 2 Viti di montaggio magnete 2 Distanziali per magnete I In nd di ic ca at to or re e L LE ED D In funzionamento normale il LED è spento eccetto che nelle seguenti situazioni Quando l interruttore tamper del contatto è aperto Quando il contatto ha la batteria scarica Quando il contatto è in modalità Test Il LED non lampeggia se il tamper e la batteria del contatto funzionano normalmente e non ...

Page 3: ... gg gi io o Esistono due modi per montare il contatto con biadesivo o con viti Montaggio con biadesivo solo in casi eccezionali I Pulire la superficie utilizzando uno sgrassatore idoneo II In base al lato di montaggio rimuovere la pellicola di protezione da uno dei lati del biadesivo e farlo aderire saldamente al retro del dispositivo III Rimuovere l altra pellicola di protezione e far aderire sal...

Page 4: ...ting mode the LED is off except for the following situations When the tamper switch of the contact is opened When the battery of the contact is flat When the contact is in Test mode The LED does not blink if the tamper switch and the battery contact are working normally and not in Test mode The LED blinks to indicate that a signal is being transmitted and blinks rapidly twice when it receives a re...

Page 5: ...h double sided adhesive tape or with screws Installation with double sided adhesive tape exceptional cases only I Clean the surface using a suitable degreaser II According to the installation side remove the protective film from one of the sides of the double sided tape and make it adhere firmly to the back of the device III Remove the other protective film and make it adhere tightly to the contac...

Page 6: ...E En nt th ha al lt te en ne es s Z Zu ub be eh hö ör r 1 Magnet 2 Schrauben 2 Dübel 1 doppelseitiges Klebeband für Magneten 2 Magnet Befestigungsschrauben 2 Abstandhalter für Magneten L LE ED D Bei Normalbetrieb ist die LED Anzeige ausgeschaltet außer in den folgenden Situationen Wenn der Tamper Schalter des Kontakts geöffnet ist Wenn die Batterie des Kontakts leer ist Wenn der Kontakt sich im Te...

Page 7: ...vorgesehen in denen Bohrungen nicht möglich sind Den Magneten mit den Kennzeichnungen des Kontakts ausrichten Wenn erforderlich den Abstandhalter für Magneten verwenden um diesen korrekt an den Kennzeichnungen auszurichten H HI IN NW WE EI IS S Bei geschlossener Tür muss der Magnet sich in einem Abstand von weniger als 15 mm vom Detektor befinden M Mo on nt ta ag ge eb be ed di in ng gu un ng ge e...

Page 8: ...z Betriebstemperatur 10 C bis 45 C Abmessungen 85 mm x 25 mm x 20 mm Gewicht 100 g Konform mit der Norm EN 50131 Grad 2 KlasseⅡ VEREINFACHTE EU KONFORMITÄTSERKLÄRUNG Der Hersteller URMET S p A erklärt dass der Funkgerätetyp WEIßER ODER BRAUNER MINI MAGNETKONTAKT DC600 DC600 BR mit der Richtlinie 2014 53 EU konform ist Der ungekürzte Text der EU Konformitätserklärung steht auf der folgenden Website...

Page 9: ...ises pour aimant L LE ED D En fonctionnement normal la LED est éteinte sauf dans les situations suivantes Lorsque l interrupteur anti sabotage du contact est ouvert Lorsque la pile du contact est déchargée Lorsque le contact est en mode Test La LED ne clignote pas si l interrupteur anti sabotage et la pile du contact fonctionnent normalement et ne sont pas en mode Test La LED clignote pour indique...

Page 10: ...s Montage avec ruban adhésif double face uniquement dans des cas exceptionnels I Nettoyer la surface à l aide d un produit dégraissant adapté II En fonction du côté de montage retirer le film de protection d une des faces du ruban adhésif et le faire bien adhérer à l arrière du dispositif III Retirer l autre film de protection et faire bien adhérer le contact dans la position désirée R RE EM MA AR...

Reviews: