9
8
W W W. I N E L S . C O M / K I T S
U S E R ´S M A N U A L 2 . 0
Power supply via terminals
INSTALLING A WIRELESS THERMOVALVE
Power supply
1. Open battery cover
2. Insert batteries (keep in mind the polarity)
3. Close the cover -> your RFATV-1 is ready to install
Mounting
Wireless thermovalve can be quickly and easily mounted on all common valves.
It can be installed without grime and water spots because the heating circuit is not interrupted.
1. Use an appropriate adapter, if required, and push it into the valve.
2. Screw the connector (connecting ring) on the valve or the adapter.
3. Put RFATV-1 into the connector (connecting ring) until it noticeably clicks into place.
The wireless thermovalve must be installed evenly to the connecting ring.
Auto calibration of wireless thermovalve
After placing a valve to vent and inserting batteries,
it is necessary to calibrate the valve on vent. It is
can be done by pressing „blue“ button directly on a
thermovalve (using the key). During this operation
please do not manipulate with the thermo valve. Auto
calibration is fi nished by a blink of green LED diode on
thermovalve.
Blue button
Green LED
Press using „the key“
Dismounting
Wireless thermo-valve can be quickly and easily
dismounted using the second side of the key.
Address
INSTALLING A WIRELESS TOUCH UNIT
Surface mounting
AC 100 - 230V / 50 - 60 Hz
Valve
Connecting
ring
Wireless
thermovalve
Adapter
Power supply through adapter
(adapter is included in the package)
2.
1.
Surface mounting by sticking
The spacing between
screws on the box
Danfoss RAV:
(The attached pin should
be mounted on the valve
tappet.)
TYPE OF ADAPTER
TYPE OF VALVE:
Danfoss
RA:
Danfoss
RAVL:
TYPE OF ADAPTER
TYPE OF VALVE:
TYPE OF ADAPTER
TYPE OF VALVE:
The spacing between
screws on the box
L
N