17
D.
Travel Limits and Stow Position Programming
Caution:
To prevent damage to the monitor controller, keep all metallic objects away from
the receiver circuit board while it is energized. Ensure all O-ring and gaskets are properly installed
when closing receiver enclosure.
Monitor can be rotated 90
left or 90
right of straight ahead. Stops are mechanically fixed by a
stop screw and milled slot in base. Stop screw must remain in place in monitor base.
Programming limits and stow position are completed during the same sequence of steps and not
independently. This is a unique programming feature to this Scorpion RF with position feedback.
1)
Move the monitor to the lower left position of the travel window.
2)
Press and release the red programming switch, SW1 (Figure 10). The setup LED DS6 will
blink twice.
3)
Move the monitor to the upper right position of the travel window.
4)
Press and release the red programming switch. The setup LED will blink three times.
5)
Move the monitor to the stow position.
6)
Press and release the red programming switch. The setup LED will blink four times.
7)
Programming of travel limits and stow position are now set.
Caution:
Limits must be programmed prior to use to avoid a collision between the monitor
discharge and the horizontal position sensor.