10
IV.
C
ONTROL
S
YSTEM
S
PECIFICATIONS
Handheld Transmitter Specifications
Input power
2 AA batteries (Alkaline recommended)
Output power
Meets FCC part 15 requirements for license free
operation
Transmitter dimensions
6” x 3 1/4” x 1 3/8”
Transmitter weight
10 ½ oz.
Operating temperature range
-40ºF to 150ºF (-40ºC to 65ºC)
FCC ID
QT8PTSS2003
Fixed Transmitter Specifications
Input power
12 VDC (11VDC to 14 VDC)
Output power
Meets FCC part 15 requirements for license free
operation
Transmitter dimensions
7 5/8” x 3 7/8” x 2 3/8”
Operating temperature range
-40ºF to 150ºF (-40ºC to 65ºC)
FCC ID
QT8PTSS2003
Receiver Specifications
Power requirements
12VDC (11VDC to 14VDC) at the controller under
full load
Control current
Operating temperature range
0.07 A
*
-40ºF to 150ºF (-40ºC to 65ºC)
Table 1
Motor Current Specifications
Monitor
Left/Right
Up/Down
Nozzle
Run I
1.0-1.5 A* at 200 psi
1.0 A* at 200 psi
0.5 A
Stall I
33.3 A
33.3 A
NA
Current Trip Point
13 A
10 A
4 A
Shock:
30 G's (55 Hz. @ .2 inch double amplitude).
Vibration:
15.5 G's (55 Hz. @ .05 inch double amplitude) continuous operation.
Drop Test:
The handheld transmitter must meet operating specifications after drop from 1-meter height onto
concrete surface.
Environmental:
All enclosures have a NEMA 4 rating (must withstand a 1 inch stream of water (65 gpm) from a
distance of ten feet for five minutes, with no water entering the enclosure).
*
All current ratings are at 12 volts