![ELKHART BRASS Cobra 7250 HD EXM Installation, Operating, & Maintenance Instructions Download Page 34](http://html1.mh-extra.com/html/elkhart-brass/cobra-7250-hd-exm/cobra-7250-hd-exm_installation-operating-and-maintenance-instructions_2393094034.webp)
34
SYSTEM SPECIFICATIONS
7250 EXM Monitor
Max Flow Rating
1500 GPM (5678 LPM)
Max Operating Pressure
250 PSI Continuous (17.2 BAR)
500 PSI Limited Duty (34.5 BAR)
[50% / 1hr (30min on / 30 min off)]
Inlet Size
3”-150# Flange, DN80-PN16 Flange, 4”-150# Flange,
3” NPT, 3” BSPT
Outlet Size
3.5” Male NHT, 3.5” Male BSPP
Travel
V: -45° to +120°
H: L175° to R175°
Movement
Sealed Electric Motors
Swing Radius
6”
Stow Height
16”
Weight
32 Lbs.
Operating temperature range -40°F to +185°F (-40°C to +85°C)
Environmental Rating
NEMA 4
Monitor Controller
Input power
12/24 VDC (11-27 VDC)
Control Communication
CAN bus J1939
2.4 Ghz digital radio frequency (unlicensed)
Electrical Load
See Table 1 Below
Fuse Rating
20 AMPS (12V) & 10 AMPS (24V)
RF power output
Meets FCC part 15 requirements for license free
operation
Operating temperature range -40
o
F to +185
o
F (-40
o
C to +85
o
C)
Environmental Rating
NEMA 4
FCC ID
KQL-2510100
7250 SD – Standard Duty Motors
Motor (12 VDC)
Left/Right
Up/Down
Nozzle
Run Current
3 A
3 A
0.5 A
Stall Current
10 A
10 A
NA
Current Trip Point
6.5 A
6.5 A
4 A
7250 HD – Heavy Duty Motors
Motor (12 VDC)
Left/Right
Up/Down
Nozzle
Run Current
5 A
5 A
0.5 A
Stall Current
70 A
70 A
NA
Current Trip Point
20 A
20 A
4 A
Table 1: Motor Current Specifications
Panel Mount Controller - 7010
Input power
12/24 VDC (11 VDC to 27 VDC)
Electrical Load
0.5 AMPS