![ELKHART BRASS Cobra 7250 HD EXM Installation, Operating, & Maintenance Instructions Download Page 30](http://html1.mh-extra.com/html/elkhart-brass/cobra-7250-hd-exm/cobra-7250-hd-exm_installation-operating-and-maintenance-instructions_2393094030.webp)
30
o
If using a panel mount or hand held, the yellow status LED on the controller will
begin to blink at once per second intervals.
o
If using Joystick, all valve LEDs will flash once to indicate that you are in USB Mode
Press and release the OPEN button. The LED above the open button will flash while the
information is being downloaded.
A diagnostic file called EBDIAG.CSV is written to the USB flash drive. When the LED
above the open button begins flashing at a 3 second interval, the download is
complete.
Remove the USB from the input controller to leave USB Mode. (On older systems it may
be necessary to push the right button on the panel mount or hand held, or move the
joystick right, to exit USB mode).
Contact Elkhart Brass to make arrangements to send the EBDIAG.CSV file for review.
O. Update Firmware
Before updating firmware ensure that all components intended for the update are
powered up and connected to the chosen input controller through either the CAN line
or RF network.
Remove the USB cover from any input controller.
o
Although any input controller may be used for updating firmware,
it is suggested
that a controller connected via the CAN line is used,
if available. Update times can
triple when using input controllers communicating over the RF network.
Install the USB flash drive with the newest firmware version into the USB port of the
desired input controller, and the controller will automatically enter USB Mode (The
following LED routines should occur to indicate that USB mode has been initiated. If USB
Mode does not initiate, hold AUX and OSC for 2 seconds and watch for the LED
indicators)
o
If using a panel mount or hand held, the yellow status LED on the controller will
begin to blink at once per second intervals.
o
If using Joystick, all valve LEDs will flash once to indicate that you are in USB Mode
Press and release the PRESET button
The input controller will read the hex file on the flash drive and install it as long as the
copied firmware is newer than the existing firmware.
o
This process will likely take up to ten minutes to complete. If using an RF input
controller, update time may be up to three times as long.
o
This action will also update all input controllers on the CAN line (primary and
secondary)
o
Once all of the input controllers are updated and there were no errors while
upgrading; then the preset LED will blink once every three (3) seconds.
o
If the primary input controller does not recognize it as newer firmware, then no
update will take place and the preset LED will flash twice every three (3) seconds.