5.  Connect a 110 VAC power supply to the water 

dispenser. Route the wiring through the wall into the 

bottom of the electrical gang box.

a.  Route the appropriate electrical wiring through a 

wiring clamp into the gang box. 

 

   

NOTICE

Do  not use a cord with a 

three-prong plug to power 

this unit.

b.  Tighten the wiring clamp to prevent the wire from 

being pulled out of the gang box.

c.  Connect black wire to supplied voltage line (black) 

wire and the white wire to neutral.

d.  Use installer provided wire nuts to insulate the 

connections.

e.  If required by code a green grounding screw can be 

used to connect a grounding wire inside the gang 

box.

f.  Reinstall the gang box cover.

Note: If the optional filter box unit is installed under the 

water dispenser, the space behind the filter box is 

limited so make sure any electrical wiring will not 

interfere with mounting the filter box into the wall. 

Refer to "4.3 Critical Depth Dimensions" on page 

6 for additional information.

If using the provided filter box, continue to "4.6 

Installing Filter Box Under Water Dispenser" on page 

8. If installing the filter remotely, advance to "4.7 

Installing a Remote Filter" on page 10. 

4.6  Installing Filter Box Under Water Dispenser

1.  First, replace the front cover of the water dispenser to 

help locate and align the filter box.

NOTICE

Attach the front cover with the 

top two mounting screws to 

prevent it from falling away from the water dispenser 

while the filter unit is being installed.

2.  Place the filter unit into the wall opening and slide it up 

against the bottom of the water dispenser. Make sure 

the filter unit is aligned with the water dispenser. 

3.  Using four #8 flathead screws, start the screws to hold 

the unit in place.  

Note:  Do not completely tighten the screws until the 

filter unit cover is installed and the fit between the 

water dispenser cover and the filter cover is checked.

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Summary of Contents for EZH20 LZWSMD*

Page 1: ...on Manual ezH2O In Wall Filtered Water Dispenser with optional Filter Box Ambient with Filter Box Chilled optional with Remote Filter WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Page 2: ...us situation resulting in personal injury or even death Do not operate power tools unless you read and understand the instructions and warnings in this and all other applicable manuals Proper use of tools and the products described in this manual is your responsibility NOTICE Failure to follow these instruc tions could also cause a situa tion that results in water damage or other damage to floors ...

Page 3: ...tion NFC device This short range wireless connectivity technology is designed to monitor the status of the filter and to alert the user when it is time to change the filter This device complies with part 15 of the FCC Rules Operation is subject to the following two 2 conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interf...

Page 4: ...ymbol and followed by a signal word such as WARNING or CAUTION 2 3 Personal Safety WARNING These warnings indicate a potentially hazardous situation which if not avoided could result in serious injury or death Follow all instructions related to the installation and or maintenance of this product unit Personal Protection Be sure to use all personal protective equipment such as sturdy safety glasses...

Page 5: ...re Cutting Make sure no electrical wiring or plumbing is present before cutting into a wall 3 Installation Preparation NOTICE The installation of this product requires electrical and plumbing connections that use specific skills and knowledge If you are unsure or not qualified to make these connections consult a qualified plumber electrician or installer for this installation Professional installa...

Page 6: ...ch Basin Drain 1 1 4 P trap and related parts Plumbers Putty Additional 3 4 drain hose if the installation requires a longer drain hose than the supplied 13 long hose 4 3 Critical Depth Dimensions 1 Make sure the wall cavity is deep enough to house the water dispenser dimension A 2 If the optional filter unit will be installed make sure there is adequate space to route electrical wiring between th...

Page 7: ...nd chiller Note When the filter is located in a remote location mount the filter vertically on a wall or other supporting structure before the water chiller Water dispenser with optional waste drain Use the following sections to install the water dispenser using the appropriate configuration 1 Cut the opening into the wall using the suggested mounting dimensions as a guide 2 Place the unit into th...

Page 8: ...wiring will not interfere with mounting the filter box into the wall Refer to 4 3 Critical Depth Dimensions on page 6 for additional information If using the provided filter box continue to 4 6 Installing Filter Box Under Water Dispenser on page 8 If installing the filter remotely advance to 4 7 Installing a Remote Filter on page 10 4 6 Installing Filter Box Under Water Dispenser 1 First replace t...

Page 9: ...s remove the front cover from the filter unit by removing the four flat head screws from the right and left side of the cover using a 3 32 Allen wrench 6 Route a 1 4 water line from the water dispenser into the filter housing outlet located on the underside of the filter head NOTICE Do not disconnect the 1 4 tubing from the water valve at the top of the water dispenser This connection has been fac...

Page 10: ...feet away from the water dispenser The remote filter location is normally associated with the installation of a water chiller 1 Remove the filter head from the filter box 2 Securely mount the filter head in the desired remote location One recommendation is to install the filter head by screwing it into a stud on the back side of a wall a Remove the short 3 8 copper inlet water tube b Remove the NF...

Page 11: ...lled and red indicator light is still ON the filter has been installed incorrectly The filter can only be installed in one direction label facing outward If the red indicator light is ON the filter is installed backwards 4 8 Remote Water Chiller optional A remote water chiller can be installed in connection with the water dispenser to supply chilled water The chiller must be installed within 15 fe...

Page 12: ...n basin 2 Place the drain basin on a flat hard surface such as a piece of sacrificial wood Carefully drill a hole in the basin using a 1 hole saw using the centering dimple as a guide to center the hole saw Note Do not use a 1 1 8 hole saw as this will make the opening too large 3 Trial fit the strainer If the strainer does not fit carefully open the size of the hole If it fits well place a small ...

Page 13: ...the two screws 8 If the filter box is used route the drain hose through the filter box Attach the other end to the p trap drain adapter using a hose clamp The drain adapter is designed to be glued into a 1 1 4 PVC pipe Shown with optional filter box 9 Install the filter by twisting it into the filter head 10 Connect the drain adapter into the waste drain pipe If the p trap is located inside a seal...

Page 14: ...spensed to prevent overflow and potential flooding so multiple activations will be required to get the required one gallon of water flow through the unit 6 If there are no leaks and the unit is functioning correctly install the water dispenser s glass front cover and then install the filter box cover if used using the flathead screws and a 3 32 hex wrench 7 Upon initial startup the PLASTIC BOTTLES...

Page 15: ... 630 574 8484 15 Elkay Manufacturing Company Installation Manual 1000005449 Rev A In Wall Filtered Water Dispenser Notes WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Page 16: ... Butterfield Rd Suite 200 Downers Grove IL 60515 630 574 8484 elkay com 2019 Elkay Manufacturing Company 1000005449 Rev A 10 9 WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Reviews: