Elkay Manufacturing Company
12
(630) 574-8484
In-Wall Filtered Water Dispenser
Installation Manual (1000005449 Rev. A)
Note: The remote chiller can take from 24 to 48 hours
to provide completely chilled water. Water lines must be
insulated to prevent condensation.
4.9 Connecting Catch Basin Drain (optional)
The water dispenser does not require a drain connection
to the wastewater plumbing. The water dispenser has a
built-in catch basin that will hold the typical overflow that
can occur when using the product.
Some local building codes, however, may require a
wastewater drain to prevent the potential overflow of
water. The following steps cover the installation of the
drain.
1. Remove the two screws attaching the drain basin to
the water dispenser. Remove the drain basin.
2. Place the drain basin on a flat, hard surface, such as
a piece of sacrificial wood. Carefully drill a hole in the
basin using a 1" hole saw using the centering-dimple
as a guide to center the hole saw.
Note: Do not use a 1-1/8" hole saw as this will make the
opening too large.
3. Trial fit the strainer. If the strainer does not fit, carefully
open the size of the hole. If it fits well, place a small
amount of plumbers putty around the lip of the strainer
flange and insert it into the hole.
4. Install the O-ring over the strainer threads.
5. Thread the strainer into the drain adapter.
Needle-nose pliers can be used to hold the drain
adapter from the top while tightening. Ensure that
the connection creates a watertight seal. The drain
adapter must be facing to the left.
Note: Twisting the strainer instead of the drain
adapter can compromise the seal created by
the plumber's putty.
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115