10.7. Traffic 

lights 

 

The controller offers potential free outputs for a green traffic light and a red traffic light (warning light). 
The green light is on, when gate is completely open. 
The red / warning light is on during movements, during warning times and when gate stops in between. 
The red / warning is off, when the gate is completely open or when it is completely closed.

 

 
 

11. 

Learn mode MO 56/S 

 

The controller must learn the following parameter during the installation: 

 

- Running time for opening and closing (Gate must be completely open when starting procedure) 
- Required force for opening and closing 
- If photocell test is needed, how many photocell are connected 

 

In addition you may alter the default values of the following parameter: 

 

- Position for partial opening (BTG) 

Force 

reserve 

     (step 

1-16, 

default 

8) 

- Pause time for automatic closure 

 

 

(0 to 300 s, default 30 s) 

- Warning time prior to closing   

 

 

(0 to 300 s, default 5 s) 

- Radio codes for BT and BTG   

 

 

(default: BT = -+-+-+-+, BTG = no code) 

 

You may use the learn button (LERN) and the LED’s Diag and SL for programming. 

 

Learn menu 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

Display: Diag: 

 SL-LED: 

{

 

BT 

LT 

Radio 

If timing logic (DIP6=OFF) 
learning running time, required force, LS-test

 

Learn radio code BT 

BT 

LT 

Radio 

Learn pause time (confirm end with BT) or 
warning time prior to closing (confirm end with LT) 

Display: Diag: 

~

 SL-LED: 

{

 

Learn radio code BTG 

BT 

LT 

Learn position BTG 

Display: Diag: 

 SL-LED: 

 

BT 

LT 

Alter force reserve 

Display: Diag: 

 SL-LED: 

~

 

Exit learn mode without changes 

Controller is in operation mode 

Press LT until Diag. lights 

BT 

LT 

Reset to default setting 

Display: Diag: 

~

 SL-LED: 

 

Delete radio code BT 

LT

 

5s

 

Delete radio code BTG 

LT 5s 

Legend: Diag.-LED: 

yellow 

 SL-LED: 

red 

{

=LED is off 

=LED lights 

~

=LED flashes fast 

z

=LED flashes in seconds

 

After each alteration the controller exits to 
operation mode. 
After altering the DIP switch mode confirm 
with the button LERN 

Summary of Contents for EST 204

Page 1: ...3 6 Mounting the rack 4 7 Electrical setup Connection examples 5 8 MO 56 S controller for EST 204 404 6 9 Operating modes MO56 DIP switches 7 10 Safety functions MO56 8 11 Learn mode MO56 9 12 After p...

Page 2: ...terminals for button BT BT BT BTA BTZ BTG Input terminal for stop yes redundant yes redundant yes Photo cell functions 2 modes testable 2 modes testable 3 modes Evaluation of safety contact strips ye...

Page 3: ...he back parallel to the gate e Mark the middle of the elongated holes on the foundation f Take the opener from the foundation and drill holes for 8 mm diameter plugs or anchor bolts g Lay the 0 5 mm c...

Page 4: ...y protrude at both ends h Hook the protruding end into the protruding end of the first length Push this rail against the first rail j Screw this length onto the distance pieces k Connect the butt join...

Page 5: ...4 404 opener control box MO 56 S section 8 EST 804 opener control box MO 43 section 10 c Check the setting of DIP switches for the functions you need EST 204 404 opener control box MO 56 S section 9 E...

Page 6: ...e photocell DIP 5 When LS is active the gate cannot be operated or the gate opens immediately Masse Ground for BT TS and LS Sync n c Button for manual release When opener is released the control box i...

Page 7: ...hen the stored time has elapsed the gate will close automatically If the gate is completely open and a stop command is given TS the function automatic closure is blocked Automatic closure will be acti...

Page 8: ...en the gate is still standing and a safety edge reports an obstacle the gate can not move in the direction of the appropriate edge Before a movement the appropriate safety edge is tested An artificial...

Page 9: ...erve step 1 16 default 8 Pause time for automatic closure 0 to 300 s default 30 s Warning time prior to closing 0 to 300 s default 5 s Radio codes for BT and BTG default BT BTG no code You may use the...

Page 10: ...e Diag LED flashes fast c Press the appropriate button on the radio transmitter Receiver and controller receive the code and store it as BTG code The SL LED flashes to confirm After this procedure the...

Page 11: ...nges into normal operation mode If a safety device has a malfunction it is not possible to operate the gate in normal operation mode into the appropriate direction But it is possible to operate the ga...

Page 12: ...opening Masse Earth for BS BZ BA BT BTG LS n c Photocell The opener reacts as determined with the operating mode DIP 1 DW Safety contact strips When activated the opener stops and reverses for a short...

Page 13: ...witch 1 off Interrupting the photo cell stops the gate during the closing phase it then re opens immediately During opening the photo cell has no effect b Switch 2 on The gate closes automatically fro...