background image

©

 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG      page  5 

                                      

EST 204, EST 404, EST 804 

7. Electrical Setup

 

 
a)  Check if the gate closes to the right or to the left. 
 
 

If the gate closes to the right as seen from the opener, the motor connectors are:  M - green  M+ red.

 

 

If the gate closes to the left as seen from the opener, the motor connectors are:  M - red 

M+ green 

 
b)  Connect all external devices 
 

EST 204 / 404 opener 

control box MO 56/S 

section: 8. 

 

EST 804 opener 

 

control box MO 43 

section: 10. 

 

c)  Check the setting of DIP switches for the functions you need. 
 

EST 204 / 404 opener 

control box MO 56/S 

section: 9. 

 

EST 804 opener 

 

control box MO 43 

section: 15. 

 

d)  Go through to learning (programming) mode 
 

EST 204 / 404 opener 

control box MO 56/S 

section: 11. 

 

EST 804 opener 

 

control box MO 43 

section: 10. 

 

Caution:  

During the learning mode the gate may move automatically several times. 

Ensure nobody will enter the gate area. 

 

The opener is ready for use.

 

 
Connection example EST 204 / 404 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Connection example EST 804

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EST 204

Page 1: ...3 6 Mounting the rack 4 7 Electrical setup Connection examples 5 8 MO 56 S controller for EST 204 404 6 9 Operating modes MO56 DIP switches 7 10 Safety functions MO56 8 11 Learn mode MO56 9 12 After p...

Page 2: ...terminals for button BT BT BT BTA BTZ BTG Input terminal for stop yes redundant yes redundant yes Photo cell functions 2 modes testable 2 modes testable 3 modes Evaluation of safety contact strips ye...

Page 3: ...he back parallel to the gate e Mark the middle of the elongated holes on the foundation f Take the opener from the foundation and drill holes for 8 mm diameter plugs or anchor bolts g Lay the 0 5 mm c...

Page 4: ...y protrude at both ends h Hook the protruding end into the protruding end of the first length Push this rail against the first rail j Screw this length onto the distance pieces k Connect the butt join...

Page 5: ...4 404 opener control box MO 56 S section 8 EST 804 opener control box MO 43 section 10 c Check the setting of DIP switches for the functions you need EST 204 404 opener control box MO 56 S section 9 E...

Page 6: ...e photocell DIP 5 When LS is active the gate cannot be operated or the gate opens immediately Masse Ground for BT TS and LS Sync n c Button for manual release When opener is released the control box i...

Page 7: ...hen the stored time has elapsed the gate will close automatically If the gate is completely open and a stop command is given TS the function automatic closure is blocked Automatic closure will be acti...

Page 8: ...en the gate is still standing and a safety edge reports an obstacle the gate can not move in the direction of the appropriate edge Before a movement the appropriate safety edge is tested An artificial...

Page 9: ...erve step 1 16 default 8 Pause time for automatic closure 0 to 300 s default 30 s Warning time prior to closing 0 to 300 s default 5 s Radio codes for BT and BTG default BT BTG no code You may use the...

Page 10: ...e Diag LED flashes fast c Press the appropriate button on the radio transmitter Receiver and controller receive the code and store it as BTG code The SL LED flashes to confirm After this procedure the...

Page 11: ...nges into normal operation mode If a safety device has a malfunction it is not possible to operate the gate in normal operation mode into the appropriate direction But it is possible to operate the ga...

Page 12: ...opening Masse Earth for BS BZ BA BT BTG LS n c Photocell The opener reacts as determined with the operating mode DIP 1 DW Safety contact strips When activated the opener stops and reverses for a short...

Page 13: ...witch 1 off Interrupting the photo cell stops the gate during the closing phase it then re opens immediately During opening the photo cell has no effect b Switch 2 on The gate closes automatically fro...

Page 14: ...LED turns off 16 2 Setup for the partial opening module The standard setup must be completed The pedestrian opening is automatically set to half of the total distance which the gate opens You may sele...

Page 15: ...ow the allocation of a channel with a one channel transmitter using the switches 8 and 9 as in the receiver Example B Receivers without code switches Logic boards MO 34 or MO 55 These receivers learn...

Page 16: ...nner the user must ascertain that no danger for himself or others will result from this use He should also ascertain that the planned use will have no detrimental effect on the appliance itself The ap...

Reviews: