Maintenance

Replacing batteries

& Warning

To avoid shock, injury, or damage to the 

equipment, remove all

the connection before opening the battery doors.

Replace the battery if the power indicator on the 

transmitter is

flashing and /or the power indicator on the 

receiver do not switch on.

To replace the battery, switch off the transmitter. 

Open the battery

doors as following photos.

Replace the 3 x 1.5V AAA (R6) batteries for the 

transmitter and

1 x 9V (6F22) battery for the receiver.

Cleaning

Wipe the case with a damp cloth and mild 

detergent. Do not

use abrasives or solvents. Dirt or moisture in the 

jacks can

affect the measurement.

Environmental Limitations

Temperature:

-10 to 50 degrees°C

14 to 122 degrees'F

Relative Humidity:

0-90%, non-condensing

Summary of Contents for 1068

Page 1: ...BRUKERMANUAL ELIT 1068 NETTVERKSTESTER MED LINJESØKER NÅR FAGKUNNSKAP KOMPETANSE TELLER ...

Page 2: ...tsinformasjonenførbruk Ikke bruk dette instrumentet rettfør under eller rett ettertordenvær Dette kanføretil elektrisk støt Sørgfor att hender klær sko ogteknisk utstyr det skalmåles på ertørt Søk ogtest kun på kabler som ikke er spennings satt Ikke ha øretelefonene i øret når de koblestilellerfra Kontroller alltid generator mottaker ogtilbehørfor skaderfør bruk Hvis instrumentet utsettesfor store...

Page 3: ...g RJ45 2 AV PÅknapp 3 Knappfor å aktivisere partesting test avkoblet kabel 4 LED indikatorer AV PÅ Tonesøker partesting og utgangssignal1 8 G 5 Knappfor aktivisering avtonesøker kabelsøker 6 Knappforfrekvens påtonesøker 7 Knapperfor hastighet på partesting treg og rask 8 Batterideksel 1 2 4 5 6 8 7 3 figur 1 ...

Page 4: ...er figur2 1 TilkoblingsterminalRJ 45 2 LED indikatorerfor partesting 1 8 G 3 Knappfor søking etter kabel tonesøking 4 Dreiehjulfor justering avsignalstyrkevedtonesøking 5 Knappfor å skru på lommelykt 6 Lommelykt 7 Sensorfortonesøking 7 4 5 3 2 1 6 ...

Page 5: ...kjermet kabel 4 Skru på senderenved å holde inneAV PÅknappen i minimum 1 sekund 5 Trykk påTONE knappen hvisTONE dioden ikke lyser konstant 6 Trykk inn og hold SØKknappen på mottakerenfor å starte søket 7 Førtuppen på mottakeren motveggen kabelbro skap eller andre steder hvor kabelen kanvære lokalisert Der mottakssignalet er høyest befinner kabelen seg Søkingettertelefonlinjer 1 Kobletilkabelmed RJ...

Page 6: ...r skalnormalt diodene løpefra 1 8 og så starte på nytt Gjør de ikke det er det f eks byttet opp ett par brudd eller kortslutning d Sendervilindikere sendt signal med lysende diode så lenge strøm går i kretsen f eks hvistråd nr 8 er kortsluttettil7 men ikke koblettil8 i andre enden 5 TREG og RASKknappenevelger hastighet på skifte mellom par For at G skallyse krever skjermet kabel Ground Vedlikehold...

Page 7: ... Never use the equipment if it just brought from a place with great temperature difference Avoid to use the equipment in the environment with strong magnetic fields strong electrostatic fields and strong RF fields Read the instruction before use and follow all safety instructions Use the equipment only as specified in the instruction card otherwise the equipment s safety features may not protect y...

Page 8: ...1 External Probe Connector 2 Power Switch 3 Cable Testing Button 4 LED Indicators 5 Cable Tracing Button 6 Tone Adjusting Button 7 Pairing Speed Adjusting Button 8 Battery Door 1 2 4 5 6 8 7 3 figur 1 ...

Page 9: ...7 4 5 3 2 1 6 1 RJ45 Connector 2 Indicators 3 Cable Tracing Button 4 Volume Adjusting Wheel 5 Flashlight switch 6 Flashlight 7 Tracing Probe ...

Page 10: ...cable with alligator clip to the transmitter 2 Connect the red clip to a wire in the unknown cable for cables with multiple wires b The outer shield for tracing a shielded coaxial cable 3 Connect the black clip to a Anotherwire in the unknown cable but not in the same pair or to ground for cables with multiple wires b The cent er conductor or ground for tracing a shielded coaxial cables 4 Switch o...

Page 11: ...signal from the environmental noise Tracing Data I LAN Cable 1 Connect the RJ 11 RJ 45 cable with the transmitter and phone jack 2 Switch on the transmitter 3 Push the SCAN button on the transmitter and the SCAN indicator will switch on 4 Activatethe receiver by pressing and holding the SCAN button 5 Move the receiver close to each phone line The line with the loudest tone is the intended line Not...

Page 12: ... TEST button and the OHM indicator will switch on the SCAN indicator flashing 4 The result of measurement is indicated over the status of green LEDs al both devices Note Press FAST or SLOW button to adjust the Verifying speed Cable Testing ffi Never use the Cable Testing features on a live circuits 1 Connect the testing cable with the transmitter 2 Switch on the transmitter 3 Push the V button and...

Page 13: ...HM indicator will switch on Note only model A has this feature CDntinuity Test 1 Plug the cable with alligator clip in the transmitter RJ 11 2 Connect the cable with alligator clip to the two ends of the testing cable 3 Switch on the transmitter 4 Push the button and the OHM indicator will switch on 5 SCAN indicator will switch on if the cable is good enough to let current pass though Note only mo...

Page 14: ...not switch on To replace the battery switch off the transmitter Open the battery doors as following photos Replace the 3 x 1 5V AAA R6 batteries for the transmitter and 1 x 9V 6F22 battery for the receiver Cleaning Wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Dirt or moisture in the jacks can affect the measurement Environmental Limitations Temperature 10 to ...

Page 15: ...Ved spørsmål service og kalibrering kontakt ELITAS Hellenvegen 9 202 GJERDRUM www elit no firmapost elit no 47 63938880 ...