![Elis SONOELIS SE 4015 Product Application, Installation And Service Manual Download Page 37](http://html1.mh-extra.com/html/elis/sonoelis-se-4015/sonoelis-se-4015_product-application-installation-and-service-manual_2389346037.webp)
Product application, installation and service manual
ELIS PLZE
Ň
a. s.
Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025
Page 37 of 44
ELIS PLZE
Ň
a. s., Lu
č
ní 15, P. O. BOX 126, 304 26 Plze
ň
, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722
Es 90 337 K/c
13. ORDER NUMBER
When you order your SONOELIS flow meter, make sure you specify correctly your requirements using the following
table to identify the correct product order number. The same table can be found on the Internet address
www.elis.cz
.
Number sequence of order number
1
2
3
4
5
6
-
7
8
9
10 11 12
ORDER NUMBER
S
E
4
0
5
Sensor design
one-beam sensor
1
double-beam sensor
2
SPECIFICATION
Dimension
200/800
0
1
of sensor
250/1250
0
2
DN/ nominal
300/1600
0
3
flow rate Q
3
350/2000
0
4
400/2500
0
5
450/3150
0
6
DN
[
mm
]
/
500/4000
0
7
Q
3
[
m
3
/h, t/h
]
600/5000
0
8
700/6300
0
9
800/8000
1
0
1000/12500
1
1
1200/16000
1
2
non-standard
0
0
Flanges
Č
SN EN 1092-1
1
ANSI B 16.5
2
BS 4504
3
JIS B 2210
4
non-standard
0
Material
carbon steel, outside painting
1
of sensor,
carbon steel, outside painting – for drinking water
2
finish
complete stainless steel without painting
3
non-standard
0
Nominal
10
1
pressure
16 only for DN 200 ÷ DN 500
2
PN
25 only for DN 200 ÷ DN 500
3
non-standard
0
Max. teperature
50
1
of measured
90
2
medium T
[
o
C
]
130
3
150
4
non-standard