Under normal operating conditions the above characters regularly replace one another. In the case of
an error due to a sensor failure, loss of a sensor signal due to a cable failure, presence of an air bubble or
a mechanical particle in the fluid flow, an “R” will appear at the last position on the first line and the “I” and “+” signs will
appear in turns at the last position on the second line of the display unit. A failure of the electronic unit will usually be
manifested by discontinued regular changes of the system status symbols on the display.
6.1.1.3 Display of measured data
Up to three measured quantities can be displayed simultaneously; one on the first line, and the other two in turns
on the second line of the display unit. The switching frequency can be selected in terms of the number of measuring
cycles per display time of one measured quantity.
Most often the first display line is used to show the volume flow rate (in m
3
/hod) or the mass flow rate (in metric
tons per hour), and the second display line to display the total volume (in m
3
) or the total mass (in metric tons)
alternatively with the fluid temperature in °C. However, the customer is free to define other combinations of the data to
be displayed and/or to select other optional data units from the software menu available.
6.1.2 Review of the measured quantities
Volume flow rate
Relative volume flow rate (in % of q
s
)
Mass flow rate
[
T
]
Relative mass flow rate (in % of q
s
)
[
T
]
Volume (aggregate value)
(volume of the fluid passed in the positive direction)
[
O
]
Volume - (volume of the fluid passed in the negative direction)
[
O
]
Mass (aggregate mass)
[
T
]
Mass + (mass of the fluid passed in the positive direction)
[
T
]
,
[
O
]
Mass - (mass of the fluid passed in the negative direction)
[
T
]
,
[
O
]
Temperature
[
T
]
Density
[
T
]
Sound propagation velocity
Fluid flow velocity through the sensor flange
Start of the measurement period (date and time of the last resetting command)
Duration of the measurement period
Duration of a meter error condition
Duration of a power failure period
Date
Time
Comment:
Quantities denoted
[
T
]
will only be measured and displayed if the meter configuration includes
a thermometer; quantities denoted
[
O
]
require that the flow meter has been set for measurements in both fluid-flow
directions.