background image

Product application, installation and service manual 

 

 

 

 

 ELIS PLZE

Ň

 a. s. 

Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 

Page 1 of 44 

 

ELIS PLZE

Ň

 a. s., Lu

č

ní 15, P. O. BOX 126, 304 26 Plze

ň

, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 

Es 90 337 K/c

 

 
 
 

Ultrasonic Flow Meter 

 

SONOELIS   SE 4015 
            SE 4025 

 

 

 
 

 

 

 
 

 
 

Summary of Contents for SONOELIS SE 4015

Page 1: ...anual ELIS PLZE a s Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 Page 1 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 722 Es 90 337 K c U...

Page 2: ...1 3 Display of measured data 13 6 1 2 Review of the measured quantities 13 6 1 3 Review of the measured quantity units 13 6 1 4 Unit conversion table 13 6 2 Keyboard control functions 13 6 2 1 Data d...

Page 3: ...ow Meter SONOELIS SE 4015 and SE 4025 Page 3 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 722 Es 90 337 K c 8 TESTING 13 9 ORDERING 13 10 PACK...

Page 4: ...the ultrasonic probes the ultrasonic ray is sent in turns in and against the fluid flow direction 3 TECHNICAL DESCRIPTION 3 1 General information The SONOELIS SE 4015 SE 4025 ultrasonic flow meter is...

Page 5: ...the fluid flow in both directions and indicate the actual fluid flow direction On request the meter sensor can be supplied in an IP 68 housing 3 2 Design specifications 3 2 1 Sensor dimensions L O D D...

Page 6: ...ted to the piping the main pipe section and two pipe branches holding the ultrasonic probes see Fig 4 In the standard sensor version the body is designed for operating pressure PN 10 made of high qual...

Page 7: ...ets The grommets are intended for tight fitting of cables of external diameter 6 to 8mm PG 9 and 4 to 6mm PG 7 At the bottom of the box there is also an earthing bolt Both the front panel and the term...

Page 8: ...5 78 75 100 156 3 200 Q1 Minimum flow rate G min 44 68 8 88 1 110 138 173 220 275 347 440 688 881 m3 h 16 25 32 40 50 63 80 100 126 160 250 320 Q2 Transient flow rate G min 70 4 110 141 176 220 277 35...

Page 9: ...for flow rate Q Q2 see Table 2 and fluid temperature up to 50 C SE 4015 0 5 for flow rate Q Q2 and fluid temperature up to 50 C SE 4025 Fluid temperature 0 150 Ambient temperature 0 50 Ambient relati...

Page 10: ...nsor are 5DN and 3DN respectively see Fig 7 FLOW DIRECTION 3 DN 5 DN 5 DN 3 DN FLOW DIRECTION Fig 7 Minimum lengths of straight piping sections Fig 8 Minimum length of straight piping section at the i...

Page 11: ...ons where there is a piping outlet into open reservoirs or tanks anywhere near see Fig 12 FLOW DIRECTION FLOW DIRECTION Fig 12 Examples of incorrect sensor placement Another factor that may influence...

Page 12: ...Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 722 Es 90 337 K c 3 0 3 0 PROBE 1 PROBE 2 Fig 13 Permitted range of one beam sensor rotation with respect to its long...

Page 13: ...atic and mechanical stresses by means of suitable installation boxes All cables shall be lead outside thermal insulation layers on piping if any Connections to the Pt 100 temperature sensor current ou...

Page 14: ...ecifications on the flange circumference Unless required otherwise the sensor shall be supplied with flanges according to standard SN EN 1092 1 the alternative solutions are ANSI or JIS flanges 5 2 3...

Page 15: ...puts and the RS 485 communication interface The X4 CANON 9 connector serves the purpose of connecting the RS 485 interface used in the meter calibration servicing and in company operational setting Th...

Page 16: ...tion on the display unit Combination of switch positions Measurement Instantaneous flow rate Measurement Instantaneous velocity Programming EEPROM programming Servicing Service The servicing mode is r...

Page 17: ...temperature range Rated pressure PN Fluid flow direction Protection class information 5 2 5 Sealing of technological meters The SONOELIS flow meters are provided with clamping and stick on factory and...

Page 18: ...ed to show the volume flow rate in m3 hod or the mass flow rate in metric tons per hour and the second display line to display the total volume in m3 or the total mass in metric tons alternatively wit...

Page 19: ...s l kg l hour kg hour 1 000 bbl 1 000 tons l min kg min bbl ton l s kg s 1 000 ft3 lb bbl hour tons hour ft3 bbl min tons min 1 000 gal bbl s tons s gal ft3 hour lb hour ft3 min lb min ft3 s lb s gal...

Page 20: ...articular operating conditions at the user s plant The push buttons T1 to T4 are provided with the following graphic symbols T1 T2 T3 T4 The push button control of the meter is shown in a schematic di...

Page 21: ...is determined by the manufacturer with respect to the meter application Provided the flow meter has been set for measurements in both directions of flow the sign before the reading indicates the flow...

Page 22: ...flow in the reverse direction 6 2 1 11 Temperature The temperature reading is only available if a thermometer is included in the meter configuration The reading sensitivity is 0 1 C 6 2 1 12 Density...

Page 23: ...ncorrect password the system will request a new password entry After three consecutive entries of incorrect passwords the system will switch over to the data display mode and will not permit further e...

Page 24: ...ed language Upon selecting the language confirm the setting by depressing push button T4 The message on the display will inform the operator of completion of the parameter setting in the newly selecte...

Page 25: ...be recorded as 03 07 01 and the time 7 minutes past 9 a m as 09 07 00 Confirm the selection by depressing push button T4 In the case of a commercial invoicing meter neither qs impulse number or sensi...

Page 26: ...ion However great care should be taken in employing this function First of all the zero flow rate condition shall be ensured make sure that the closing valve in the piping is not leaking Only then the...

Page 27: ...appear on the display LIQUID DOES NOT FLOW Check the zero flow rate condition and depress and release S1 The test will continue by checking whether the passage route for the ultrasonic ray in one dire...

Page 28: ...e meter needs be put out of service and either sent for repair to the manufacturing plant or a service technician be asked to come and repair the meter on site Should a fault be indicated at the ultra...

Page 29: ...on and service manual ELIS PLZE a s Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 Page 29 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 72...

Page 30: ...on and service manual ELIS PLZE a s Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 Page 30 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 72...

Page 31: ...on and service manual ELIS PLZE a s Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 Page 31 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 72...

Page 32: ...lation and service manual ELIS PLZE a s Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 Page 32 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 51...

Page 33: ...on and service manual ELIS PLZE a s Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 Page 33 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 72...

Page 34: ...on and service manual ELIS PLZE a s Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 Page 34 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 72...

Page 35: ...ncluding natural disaster A requirement for warranty repair shall be communicated to the manufacturer by a notice in writing by e mail fax or registered letter Should the manufacturer find the warrant...

Page 36: ...015 system optional assembly and testing fixtures this manual a statement on the product compliance and delivery note 12 WARRANTY CONDITIONS Unless agreed otherwise between the manufacturer and custom...

Page 37: ...ORDER NUMBER S E 4 0 5 Sensor design one beam sensor 1 double beam sensor 2 SPECIFICATION Dimension 200 800 0 1 of sensor 250 1250 0 2 DN nominal 300 1600 0 3 flow rate Q3 350 2000 0 4 400 2500 0 5 4...

Page 38: ...3 0 1 for remote 5 0 2 version m 7 0 3 10 0 4 15 0 5 20 0 6 30 0 7 40 0 8 50 0 9 60 special cabel 1 0 70 special cabel 1 1 80 special cabel 1 2 90 special cabel 1 3 100 special cabel 1 4 non standard...

Page 39: ...Q4 4 20 mA 3 non standard 0 Binary not required 0 1 output fluid flow direction upstream switch on 0 2 fluid flow direction upstream switch off 0 3 total fluid volume level on exceeding switch on 0 4...

Page 40: ...l min 0 6 l s 0 7 bbl h 0 8 bbl min 0 9 bbl s 1 0 ft3 h 1 1 ft3 min 1 2 ft3 s 1 3 gal h 1 4 gal min 1 5 gal s 1 6 Q4 1 7 non standard 0 0 Units of volume is not pictured 1 volume m 3 2 m 3 10 3 3 l 4...

Page 41: ...ver lich sud ls 3 O of flow sud sud ss 4 M meter lich lich ll 5 U Group 000 0 0 0 N 001 0 0 1 I 002 0 0 2 C A T I 255 2 5 5 O Address 000 0 0 0 N 001 0 0 1 002 0 0 2 255 2 5 5 CALIBRATION Calibration...

Page 42: ...47 48 49 50 51 52 ORDER NUMBER DELIVERY TERMS Number of 1 piece 0 0 1 pieces 2 pieces 0 0 2 3 pieces 0 0 3 999 pieces 9 9 9 1000 pieces or more 0 0 0 Packing no packing 1 standard 2 export 3 non stan...

Page 43: ...tallation and service manual ELIS PLZE a s Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025 Page 43 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377...

Page 44: ...SE 4025 Page 44 of 44 ELIS PLZE a s Lu n 15 P O BOX 126 304 26 Plze Czech Republic tel 420 377 517 711 fax 420 377 517 722 Es 90 337 K c Manufacturer s address ELIS PLZE a s Lu n 15 P O BOX 126 304 26...

Reviews: