ELIS PLZEŇ a. s.
Design, Assembly and Service Manual
Page 29 of 32
Electromagnetic flowmeter FLONET FN50xx.1
ELIS PLZEN a. s., Lucni 425/15, 301 00 Plzen, Czech Republic, Phone: +420/377 517 711, fax: +420/377 517 722
Es90716K
Position in order number
13 14 15 16 17 18 19 20 - 21 22
Material of electrodes and
grounding rings
stainless steel 1.4571
1
hastelloy C-276
2
non-standard
X
Sensor lining
hard, soft rubber (0 to 80 °C, DN20 to
DN800)
1
teflon PTFE (-20 to +150 °C, DN15 to DN250)
2
E-CTFE (-20 to +130 °C, DN300 to DN800)
3
non-standard
X
Sensor protection
standard IP 65
1
Grounding
sensor to piping
1
grounding electrode
2
grounding rings
3
Nominal pressure PN
[bar]/psi [lb/in²]
10/150
1
16/150
2
40/600
3
Maximum
temperature
of measured
fluid [ °C ]
50
1
80
2
130
3
150
4
Length of cables
3
1
6
2
10
3
15
4
non-standard
X
Power supply
85 ÷ 305 VAC, 47 ÷ 440 HZ
1
FLOW METER SETTINGS
Measurement in sensitivity
standard ±0,5 % Qmax
1
non-standard
X
Number of
samples for
averaging
25
1
50
2
100
3
150
4
200
5
250
6
non-standard
X