Electromagnetic flowmeter FLONET FN50xx.1
ELIS PLZEN a. s., Lucni 425/15, 301 00 Plzen, Czech Republic, Phone: +420/377 517 711, fax: +420/377 517 722
Es90716K
4.1.9. Technical data of sensor
Dimensions of sensor
Flangeless DN 25 to DN 200
Flanged DN 15 to DN 800
Operating pressure
PN 40 (4,0 MPa) for DN 15 to DN 50
PN 16 (1,6 MPa) for DN 65to DN 200
PN 10 (1,0 MPa) for DN 250to DN 800
Connection of sensor
Flangeless
Flanged
Earthing
Earthing electrode
Flow rate of measured liquid
0,05 m/s to 10 m/s (range 1:200)
Temperature of measured liquid
110
o
C
Up to 150ºC on a request (based on lining type and
when using sensor with prolonged chimney made of
stainless material)
– see article 4.1.4
Minimum conductivity of measured liquid
20 μS/cm, based on agreement with manufacturer up
to 5 μS/cm
Lining
Soft rubber
Hard rubber
Rubber for potable water
Teflon PTFE
E - CTFE
Electrodes
Stainless steel 1.4571 (316Ti)
Hastelloy C276
Tantalum
Titanium
Platinum-Rhodium (PtRh10)
Ingress protection
IP 65
Storage temperature
-
10ºC to +70ºC, at the max. relative humidity 70 %