81
English
(2)
• Open both shielding panels (see § AP.A-P1).
• Remove the discharge belt conveyor (see § AP.A-P2).
• No tools required for opening the sieve screen, it
comes with a manual quick-closing device
(1)
.
• Pull the black lever towards you to relieve the tension
of the tension hooks.
• Swing the hooks away by turning the
black rubber defl ector in the upward direction.
• Open the sieve downwards using the handle of the sieve screen.
• To remove the sieve screen completely, simply remove the peg from the pivot point of the sieve.
• Remove the hairpin clip found on the left hand-side of the machine.
• Remove the peg using the handle.
• Prior to refi tting the sieve, apply a small amount of grease to the peg
for a true sliding fi t in the pivot point.
Caution:
Ensure the peg is indeed inserted all the way in the hinges up to against the
sieve in such a way as to avoid the peg from opening when the machine is run-
ning, which may otherwise damage the discharge belt conveyor.
• If you notice on closing the sieve that there is insuffi cient tension
on the hooks serving to clamp shut the sieve, adjust the hooks.
• Partially unscrew the nuts from the hooks (open-ended spanner 13)
and secure the hooks one turn (clockwise).
(2)
• Close the sieve and check for adequate tension.
• If so, retighten the nuts.
• If not, turn the hooks inwards and repeat the operation above.
Caution:
Never run the engine with the quick disconnects disconnected from the
hydraulic hoses. Failure to do so may seriously damage the hydromotors.
(1)