Safety Functions
- 71 -
13.3
Safety Functions during Commissioning
During commissioning (LIMAX33 CP-00 is in Teach mode
11.1) the system fulfils the safety functions listed in
the table below:
Table 17: Safety functions during commissioning
Name
Norm reference
SIL
Comments
Overspeed
(pre-tripping)
EN 81-1 9.9.11.1
SIL 2 Same as in normal mode
Overspeed
(final-tripping)
EN81-20 §5.6.2.2.1.1a.)
SIL 3 Same as in normal mode;
Final
limit switches
EN81-20 §5.12.2.3.1.b.)
SIL1 Always closed
Inspection
limit switches
EN81-21 §5.5.3.4 / § 5.7.3.4 SIL2 If reference positions are available: same as in normal
mode. Always opens if reference positions are not
available
Supervision on
inspection direction
no norm reference
SIL2 Same as in normal mode
Pre-triggered
stopping system
EN 81-21 §5.5.2.2 / §5.7.2.2
SIL3 If reference positions are available: Same behavior as
in normal mode
If reference positions are not available: pre-triggered
stopping system will always trip in EN81-21-state
Overspeed inspection
(pre-tripping)
EN81-20 §5.12.1.5.2.1 e.)
No
SIL
Same as in normal mode
Overspeed inspection
(final tripping)
no norm reference
SIL3 Same as in normal mode
Overspeed teach
(pre-tripping)
Additional function,
no norm reference
SIL3 Protection in teach mode. Substitute for ETSL, which is
not carried out in tach mode. OC opens if speed
exceeds pre-tripping speed teach. “Pre-tripping speed
teach” is a fixed configuration parameter
14.1. This
safety function is reset (and therefore OC closes) in
case standstill is reached and hold for 1s.
Overspeed teach
(final-tripping)
Additional function,
no norm reference
No
SIL
Protection in teach mode. eSGC opens additionally to
the OC if the speed exceeds final-tripping speed
teach. Final-tripping speed teach is a fixed configura-
tion parameter
After tripping of this safety function, eSGC is kept open
even after stand still. This state is stored in a non-
volatile way: eSGC will also remain open after a pow-
er cycle. This state is cleared by manual reset by RESET
(by CANopen).
Working platform
EN81-20 §5.2.6.4.3.1 b.)
SIL 3 Same as in normal mode
No door bridging and no UCM are active in teach mode.
SR1 and SR2 are always open in teach mode
Summary of Contents for LIMAX33 CP-00 SERIES