During Operation
- 55 -
Table 11: Errors concerning nonvolatile stored data
Name
Error codes
Measures
Shaft parameter
(offset final limit switch,
offset inspection limit
switch)
1.
0x643
2.
0x644
3.
0x662
4.
0x663
Go to settings or teach mode.
Set new shaft parameter or set them to default.
Shaft references
(reference position for the
limit switches)
1.
0x645
2.
0x646
3.
0x664
4.
0x665
Go to Pre-Commissioned mode.
Make a power cycle.
Redo the teach-process.
Floor table
1.
0x647
2.
0x648
3.
0x666
4.
0x667
Go to Pre-Commissioned mode.
Make a power cycle.
Redo the teach-process.
Floor parameter
(number of floors, valid
flag)
1.
0x649
2.
0x64A
3.
0x668
4.
0x669
Go to Pre-Commissioned mode.
Make a power cycle.
Redo the teach-process.
Door parameter
(relevelling zone size,
levelling zone size, mini-
mum distance)
1.
0x64B
2.
0x64C
3.
0x66A
4.
0x66B
Go to settings or teach mode.
Set new door parameters or set them to default.
Safety Functions
(state of the safety func-
tions)
1.
0x64d
2.
0x64e
3.
0x66C
4.
0x66D
Make two system resets.
Legend:
1.
CRC mismatch to EEPROM (at initialization)
This can happen,
if the store was not successful, caused by power cycle
or an EEPROM error
2.
Channel CRC mismatch (at initialization)
This can happen,
if the store was not successful on one channel, caused by power cycle
or an EEPROM error
3.
CRC mismatch to EEPROM (at runtime)
This can happen,
if the store was not successful, caused by power cycle (consequence of 1.)
or an EEPROM error or RAM error
4.
Channel CRC mismatch (at runtime).
if the store was not successful, caused by power cycle (consequence of 2.)
or an RAM error