Configuration and Functions
- 33 -
Language
German
English
Axes active
Bac Gap + Angle
Bac Gap
Bac Angle
Backgauge
Mode pieces counter single block
The mode pieces counter for the single mode can be defined here.
Without counter
Automatically subtracting
Automatically adding
Mode pieces counter program
The mode counter fort he program mode can be defined in this parameter.
automatically subtracting
automatically adding
Block size
1
5
10
20
25
50
75
100
Block
shift
Auto start after changing a set is defined in this parameter.
Not active
After set without start
After set with start
Time Block shift
The time frame from the end of a set to the start oft he new set is defined in this parameter.
1/2/3/4/5 sec.
Cutting length
not active