Configuration and Functions
- 20 -
Software-end position MIN/MAX
These two values can be used if no mechanical limit switches are present or additionally for already
existing mechanical limit switches.
End position min.: This value should be between the smallest length/position that hast o be worked
off and zero (and shortly before the mechanical limit switch respectively).
End position max.: This value should be between the largest length/position that has to be worked
off and the maximum length (and shortly before the mechanical limit switch respectively). If one of
these two values is reached, the positioning procedure is interrupted.
Factor
A factor (0.00001 to 9.9999) can be entered in this Register. The incoming pulses will be multiplied
by this factor, to manipulate the display to required dimensions. If no multiplication is required, this
Register must be set to 1.00000.
Example:
rotary encoder = 1000
[RPM]
]
pulses
[
Spindle distance = 100
[ ]
[
]
RPM
mm
]
pulse
[
]
mm
[
1
,
0
]
pulses
[
1000
]
mm
[
100
pulses
]
mm
[
distance
Spindle
Factor
=
=
=
Blade length
Here, the maximum blade length can be entered (in mm). With this the maximum input length of the
cutting length in single mode and program mode will be defined. If no blade length (parameter
value = 0) will be defined, the cutting length in single or program mode will be percentage
calculated.