Technical Data
- 10 -
6.3
Technical Data MTM-A-000
MTM-A-000 (standard version)
Mechanical Data
Measurement principle
absolute
Repeat accuracy
± 1 increment
System accuracy
± 1 mm at max. 2450 mm measurement length (standard)
Distance sensor - round rod
1.0 mm with 10 mm wide coding
1.5 mm with 20 mm wide coding or all-round coding
Round rod diameter
min. 20 mm
Round rod coding
Standard: coded magnetic track (10 or 20 mm wide)
Optionally: coded total scope (possible on request)
Measuring length
max. 2450 mm (available in 10 mm steps
Sensor housing material
galvanized aluminium
Sensor housing dimensions
L x W x H = 52 x 16 x 30 mm
Sensor cable length
standard: 1.5 m (others on request)
Weight
approx. 50 g without cable (cable: approx. 60 g/m)
Mounting position MTM-A system
depends on application
Electrical Data
Power supply voltage
10 … 30 VDC
Residual ripple
10 … 30 VDC <10 %
Consumption
max. 80 mA
Available Interfaces
(depends on order
CANopen standard (DS406)
12 bit analog output (0 … 20 mA)
12 bit analog output (4 … 20 mA)
12 bit analog output (0.5 … 4.5 V)
12 bit analog output (0 … 10 V)
Connection type
(depends on order
Standard: open cable ends
Option: 5-pin M12 x 1 round connector
Maximum operating speed
up to 2.0 m/s
Environmental Conditions
Store temperature
−25 … +85° C
Operating temperature
−25 … +85° C
Humidity
max. 95 %, none-condensing
Protection class (entire system)
standard: IP65 / optionally: IP69K (see section
Influence of external magnet on
the coding of the round rod
External magnetic fields must not exceed 64 mT (640 Oe; 52 kA/m) on
the coded round rod surface (comparable to a rare earth magnet), as
this can damage or destroy the round rod coding.
6.4
Usable Round Rod Diameters
Available round rod diameters acc. to ISO 3320: 20, 22, 25, 28, 32, 36, 40, 45, 50, 56, 63, 70, 80, 90,
100, 110, 125, 140, 160, 180, 200, 220, 250, 280, 320 and 360 mm
6.5
Usable Cylinder Diameters
Available cylinder diameters acc. to ISO 3320: