Installation and First Start-Up 

- 16 - 

GND

TEACH

Signal cable

red wire

4

1

2

5

3

GND

TEACH

Standard                   Connection option R5M0

8.4

 

Calibration of the Measuring Range 

8.4.1

 

Calibration for Versions with CAN Interface 

A hardware calibration as described in section 

 8.4.2 is not required for this version. 

The calibration of the upper and lower set point is performed via the CANopen interface. 

8.4.2

 

Calibration for Versions with Analog Output 

 

 

 

REMARKS 

 

The calibration must be performed for each newly installed MTM-A-000  
measuring system before or during commissioning. 

 

Even when replacing the measuring system or rod (e. g. in case of servicing)  
a new calibration must be performed. 

 
One second after power-up, the device is ready for operation. In 
addition, the MTM-A-000 system with analog output offers the 
possibility of initiating the learning process during the first ten 
seconds after power-up. A lower and upper set point must be de-
fined for which the TEACH input is required. 

 
Ideally, this input is - temporarily for the calibration procedure - 
wired with a switch or push-button against GND (see figure).  
 
To calibrate the set points, please proceed as follows:

 

Starting position = TEACH input is open resp. not activated.  

 Press the connected TEACH button.  

During the first second of pressing, the LED changes rapidly between red and green. 
a) Keep the button pressed within 1 … 3 seconds, until the LED lights statically green: 

    

 By releasing the button in the green phase, the learning of the lowest position (min) is initiated. 

b) Keep the button pressed (max. 8 seconds), until the LED lights statically red: 

    

 By releasing the button in the red phase, the learning of the uppermost position (max) is initiated. 

Outside these times, the learning process is interrupted. 

8.4.2.1

 

Teach Set Point 1 (Min)  

Move the round rod to the lower set point (e.g. zero point) and release the TEACH button during the green 

phase.  

 

 
3 x flashing, followed by 3 x pressing button 

  stores the lower set point.  

This is confirmed by the LED with a single green hold for 1.5 seconds. 
 

 

Set point 1 (Min position)

Figure 8: TEACH input wiring

 

Summary of Contents for MTM-A-000 Series

Page 1: ...ion Position path determination at round profile rods Wear free contactless measurement principle Very robust and proven measuring technology Interface Analog output or CANopen High shock and vibratio...

Page 2: ...z Str 1 D 78239 Rielasingen Worblingen Technical Support 49 0 7731 9339 0 49 0 7731 2 88 03 info elgo de Document No 799000850 Document Name MTMA 000 MA E_10 19 Document Revision Rev 0 Issue Date 2019...

Page 3: ...Product Features 8 5 1 Principle of Scanning 8 5 2 The absolute Measuring Principle 8 5 3 Available Output Signals 8 6 Technical Data 9 6 1 Identification 9 6 2 Dimensions of the MTM A Standard Housi...

Page 4: ...le via mounting ring 12 Figure 5 Alignment of the active sensor area 14 Figure 6 Adjustment of reading distance and lateral offset 15 Figure 7 Angular tolerances 15 Figure 8 TEACH input wiring 16 Figu...

Page 5: ...r to avoid accidents damage and injuries Warning notes DANGER This symbol in connection with the signal word Danger indicates an immediate danger for the life and health of persons Failure to heed the...

Page 6: ...evice if you have understood the operating manual The operating company is obliged to take appropriate safety measure The initial operation may only be performed by qualified and trained staff Selecti...

Page 7: ...ally Do not throw hit or fold it 4 9 Handling of Packaging Material Notes for proper disposal 4 4 4 10 Inspection of Transport Check the delivery immediately after the receipt for completeness and tra...

Page 8: ...A or Volt From here it can be further processed by the subsequent electronics 5 2 The absolute Measuring Principle The absolute measuring principle ensures maximum safety as the current position value...

Page 9: ...gives the exact type designation 11 with the corresponding part number Furthermore the type label con tains a unique traceable device number When corresponding with ELGO please always indicate this da...

Page 10: ...pple 10 30 VDC 10 Consumption max 80 mA Available Interfaces depends on order 11 CANopen standard DS406 12 bit analog output 0 20 mA 12 bit analog output 4 20 mA 12 bit analog output 0 5 4 5 V 12 bit...

Page 11: ...Technical Data 11 40 50 63 80 100 110 120 125 160 200 250 320 and 400 mm...

Page 12: ...d sensor housing 6 2 d Identical to c but in reverse mounting direction On request and at an extra charge the required mechanical accessories for sensor adaptation can be provided by ELGO Electronic G...

Page 13: ...or 8 1 Operating Area WARNING Do not use the device in explosive environments The device must not be installed close to sources of strong inductive or capacitive interference or strong electrostatic f...

Page 14: ...solute coding The center of the sensor pitch line is located at a distance of 5 mm from the outer edge of the sensor housing see figure Figure 5 Alignment of the active sensor area Hint To make the ma...

Page 15: ...Mounting tolerances Coding Order index Reading distance Lateral offset Pitch Roll Angle Yaw Angle 10 mm 1 11 max 1 mm max 1 0 mm see figure 7 1 0 20 mm 2 11 max 1 5 mm max 2 0 mm see figure 7 1 0 All...

Page 16: ...or which the TEACH input is required Ideally this input is temporarily for the calibration procedure wired with a switch or push button against GND see figure To calibrate the set points please procee...

Page 17: ...y for operation with the newly taught in scaling 8 4 2 3 Possible causes of faulty teaching If after teaching a set point the LED finally appears red instead of green for 1 5 seconds the key sequence...

Page 18: ...able for the MTM A 000 system order information see 11 For the version with plug connector a 5 pin M12 x 1 round connector is used 9 1 1 Open Cable Ends Standard Figure 9 Standard connection open cabl...

Page 19: ...sition step of 700 m corresponds to a DAC change of 4095 uppermost teach position lowermost teach position For more information about the TEACH positions see 8 4 2 Calibration for Versions with Analog...

Page 20: ...ptions and further information about the DS406 device profile can be found in the downloadable EDS and XDD file Download link https www elgo de fileadmin user_upload software MTMQ_DS406 zip 9 1 1 Conn...

Page 21: ...ia the different motor phases in the terminal box of the motor 4 Do not connect protective earth and ground 5 Connect a mains filter ahead of the external power pack 10 2 Re start after Fault Clearanc...

Page 22: ...g current 4 20 mA CA0 CANopen standard DS406 Connection options 0 open cable ends standard 2 5 pin round connector M12 x 1 at signal cable X XXX System accuracy 01 1 mm at max 2450 mm measuring length...

Page 23: ...23 Notes...

Page 24: ...evice number 9 Dimensions MTM A 9 Disposal 6 Disturbances 20 Explanation of symbols 5 Fault clearance 20 First start up 12 Identification 9 Installation 12 Installation of the sensor 13 Integration Ex...

Page 25: ...e MTMA 000 MA E_10 19 Subject to change 2019 ELGO Electronic GmbH Co KG ELGO Electronic GmbH Co KG Measuring Positioning Control Carl Benz Str 1 D 78239 Rielasingen Fon 49 0 7731 9339 0 Fax 49 0 7731...

Reviews: