![ELGO Electronic MTM-A-000 Series Operating Manual Download Page 14](http://html1.mh-extra.com/html/elgo-electronic/mtm-a-000-series/mtm-a-000-series_operating-manual_2388655014.webp)
Installation and First Start-Up
- 14 -
8.2
Installation of the Sensor
8.2.1
Alignment of the active Sensor Area
In the case of a 10 mm or 20 mm wide, single-track coded rod, the sensor housing must be positioned so that
the center of the sensor pitch line is in the center of the magnetic absolute coding. The center of the sensor pitch
line is located at a distance of 5 mm from the outer edge of the sensor housing (see figure).
Figure 5: Alignment of the active sensor area
Hint:
To make the magnetically coded track visible during alignment,
the pole finder foil (Art. No.: 710000130) can be used, which
is available as an accessory (
5 mm
Round rod
Absolute coding
Sensor housing
Side cover
Center of the sensor pitch line
Mounting ring
Magnetic track center
Round connector (option)