LanConn-400 User’s Guide
7
Click the [Update] button to update the parameters.
IP Address
4 numbers separated by dots, assigned by the server under DHCP mode.
Subnet mask
4 numbers separated by dots, assigned by the server under DHCP mode.
Gateway address
4 numbers separated by dots, assigned by the server under DHCP mode.
Network link
speed
Auto : Auto select ; 10 M : Forced to 10 Mbps ; 100 M : 100 Mbps
DHCP client
If disabled, then IP address, Subnet masks and Gateway address must be
assigned manually.
Socket port of
HTTP setup
If disabled, then IP address, Subnet masks and Gateway address must be
assigned manually.
Socket port of
serial I/O
•
Port Number: any number between 1 and 65536, can be assigned to port
80 and 81. this function allows users build their own Web pages.
•
Socket Type
TCP Server, uses TCP protocol, passively waits for Client.
TCP Client, uses TCP protocol, actively connects to Server.
UDP Client, uses UDP protocol, exchanges packets with Server
without connection.
Client mode
server IP address
The server IP address under TCP Client or UDP Client mode.
Client mode
server socket port
Any Valid port can be assigned (1-65535),
Serial port settings
( Port #1, Port #2)
(baud rate, parity,
data bits, stop bits)
•
Baud Rate: 300 - 230400 bps
•
Parity : N,E,O.
Data bits : 5.6.7.8.
Stop Bit: 1 or 2.
Serial port settings
( Port #3, Port #4)
(baud rate, parity,
data bits, stop bits)
•
Baud Rate: 300 - 230400 bps
•
Parity : N,E,O.
Data bits : 6.7.8.
Stop Bit: 1 or 2.
Interface of serial
I/O
•
RS232: use only TxD and RxD to transfer and receive data.
•
RS232 (RTS/CTS):
TxD, RxD – transfer and receive data.
RTS/CTS – flow control.