background image

LanConn-400 User’s Guide 

5

6. Browser Configuration

 

LanConn-400 supports the HTTP communication protocol. All device configurations can be easily 

set in the browser program. Just type in the LanConn-400’s IP address, and the following screen will 

be displayed. 

 

 

 

The following basic information is shown in the display. 

 

 

System time elapsed:

 

The elapsed time since the system was turned on. In the screen 

shown above, the elapsed time is 0 hour 0 minute and 9 seconds. This information can be used to 

determine if the device has been operating normally without being reset

.

 

 

   

Firmware release date:

 

This is used to identity the firmware version of the LanConn-400 

device. 

 

 

Ethernet address:

 

The Ethernet address has 6 hex-decimal bytes

.  

 

Now, type in the password and click the [Login] button to enter the configuration screen. Note that 

initially the password is not required, just click the [Login] button.   

 

Summary of Contents for LanConn-400

Page 1: ...LanConn 400 User Guide User s Manual First Edition C 2002 2003 Eletech Enterprise Co Ltd All Rights Reserved ...

Page 2: ... with 4 serial ports and 1 keyboard port making it a powerful and cost effective solution to many applications such as industrial automation and remote Internet enabled device control 2 System Structure 3 Specifications Hardware Samsumg S3C4500A ARM7 CPU 25 MHz 2MB DRAM 128 KB Flash ROM Realtek 8201BL Ethernet PHY Protocol ARP IP UDP TCP ICMP HTTP DHCP Interface 10 100 Mbps 300 230400 bps asynchro...

Page 3: ... DCD DTR DSR RI GROUND RXD TXD CTS RTS 1 6 2 7 3 8 4 9 5 DCD DTR DSR RI GROUND RXD TXD CTS RTS 1 6 2 7 3 8 4 9 5 DCD DTR DSR RI GROUND 1 2 3 4 RS422 RS485 rsRx rsRx rsTx rsTx 1 2 3 4 5 6 PS 2 Mini DIN VCC DATA CLOCK GND 1 2 3 4 5 6 7 8 RJ45 Tx Tx Rx Rx DC9V Serial Port 1 Serial Port 2 Serial Port 3 Serial Port 4 Keyboard RS422 RS485 Network Power ...

Page 4: ...resh function or press the F5 key the system will re detect the devices and update the screen accordingly Because Etm exe uses UDP Broadcast Packets it has the following characteristics It s not subject to the subnet restriction the program is usable even if LanConn 400 s IP and the PC s IP are not on the same subnet Since broadcast packets cannot pass through the router only the devices on the sa...

Page 5: ...nConn 400 User s Guide 4 IP Address Enter the new IP address and click OK Or click Cancel to abort the operation Subnet Mask Enter the Subnet Mask value and click OK Or click Cancel to abort the operation ...

Page 6: ...apsed time since the system was turned on In the screen shown above the elapsed time is 0 hour 0 minute and 9 seconds This information can be used to determine if the device has been operating normally without being reset Firmware release date This is used to identity the firmware version of the LanConn 400 device Ethernet address The Ethernet address has 6 hex decimal bytes Now type in the passwo...

Page 7: ...LanConn 400 User s Guide 6 If the correct password is not entered in three tries you have to wait at least 20 minutes to try again The following is an example of the configuration screen ...

Page 8: ...e assigned to port 80 and 81 this function allows users build their own Web pages Socket Type TCP Server uses TCP protocol passively waits for Client TCP Client uses TCP protocol actively connects to Server UDP Client uses UDP protocol exchanges packets with Server without connection Client mode server IP address The server IP address under TCP Client or UDP Client mode Client mode server socket p...

Page 9: ...s connected The format is Serial port 1 nnnnnA Serial port 2 nnnnnB Serial port 3 nnnnnC Serial port 4 nnnnnD Keyboard port nnnnnE There are eight bytes nnnnn is the 5 digit device ID LF is decimal 10 and CR is decimal 13 Setup password The login password can be empty of 1 to 15 characters long If the password is empty then no password is required for login Access password This is the password for...

Page 10: ...parity data and stop bits 9600 None 8 1 Serial Port 3 Socket port 102 TCP Server Interface RS 232 Baud rate parity data and stop bits 9600 None 8 1 Serial Port 4 Socket port 103 TCP Server Interface RS 232 Baud rate parity data and stop bits 9600 None 8 1 Keyboard Input Socket port 104 TCP Server ...

Page 11: ...0 User s Guide 10 After clicking on the Update button the following screen will appear At this point LanConn 400 is restarting with the new parameters In about 5 seconds the system will return to the Login screen ...

Page 12: ... RS 232 connector Plug the null modem on LanConn 400 s RS 232 connector 2 Connect LanConn 400 onto the LAN into the same subnet as the testing PC 3 Execute Hypertrm exe The following screen will appear 4 Key in your favorite name and click the OK button The following screen will appear IP Address Socket port of serial I O ...

Page 13: ...ers will be looped back through the null modem and displayed on the screen Note that Rx will flash once whenever you type in a character to indicate the receiving of that character You may also send a text file and it will be displayed on the screen However you should not use the Send File function because the transmission protocols such as Zmodem will cause Hyperterminal to reset LanConn 400 Char...

Reviews: