3.8.1 Teaching in hand-held/wall transmitters, clock
transmitters
When teaching in hand-held/wall transmitters and trans-
mitters with clock function, the switching condition (
ON
or
OFF
) may be taught in in any assignment to the
UP
/
DOWN
running commands of the sensors.
Teaching in switching condition
ON
:
Push the button
UP
or
DOWN
once while the light is
flashing quickly to set a hit.
Teaching in switching condition
OFF
:
Push the button
DOWN
or
UP
once while the light is
flashing slowly to set a hit.
Teaching is completed.
If several transmitters from the group of the hand-held/
wall transmitters and from the ground of clock transmitters
are taught in to the Unio-868, the last transmitter taught in
determines the assignment of all transmitters to this group.
• Important:
The Unio-868 does not react to manual central channel
commands.
3.8.2 Teaching of sensors (sensor transmitters)
When teaching in sensors (sensor transmitters), the switch-
ing condition (
ON
or
OFF
) may be taught in in any assign-
ment to the
UP
or
DOWN
buttons of the Unio-868.
Teaching in switching condition
ON
:
Push the button
UP
or
DOWN
once while the light is
flashing quickly to set a hit.
Teaching in switching condition
OFF
:
Push the button
DOWN
or
UP
once while the light is
flashing slowly to set a hit.
Teaching is completed.
If several sensors have been taught in to the Unio-868, the
last sensor taught will determine the assignment of all sen-
sors from the sensor transmitter group.
• Important:
Wind sensors have a higher priority than light sensors
where assignment of the switching conditions is con-
cerned.
3.8.3 Deleting a taught-in transmitter in the
Unio-868
→ see transmitter instructions
3.8.4 Deleting all taught-in transmitters in the
Unio-868
→ see transmitter instructions
4
Technical Data
Operating voltage [V / Hz]
(supply voltage)
198 ... 253 / 50 ... 60
Power consumption [W]
< 0.5 (stand by)
Switching output [VA]
max. 2300 VA
Radio frequency [MHz]
868
Transmission power [mW]
10
Effective range [m]
up to 100 (free field)
approx. 30 (in buildings)
Permitted
ambient temperature [°C]
0 to 55
Dimensions (L x W x H)
[mm]
110 x 60 x 40
(without plug)