3.4  Bidirectional radio system 

The term bidirectional radio system means the transmission 

of radio signals to radio receivers and the response option 

for the radio receivers to the transmitter. The radio signal 

can be sent directly to the target receiver. If this is not pos-

sible, the radio signal will be routed via other bidirectional 

participants until it reaches the target receiver. The target 

receiver carries out the command and sends a confirmation 

back to the transmitter. The prerequisite for a bidirectional 

radio system is hence the radio transmitting capability as 

well as the radio reception capability of all participating 

components. 

3.5  Unidirectional radio system 

A unidirectional radio system transmits radio signals to radio 

receivers. However, unlike in a bidirectional radio system, 

the radio receiver cannot send any message back to the 

transmitter. It is also not possible to transmit radio signals 

from radio receiver to radio receiver. 

3.6  Preparations for operation 

WARNING!

  

Danger of injury due to electric current. 

 

‰

Protect yourself from electrical shock. Use the corre-

sponding care when handling electrical current. 

Plug the Unio-868 into a mains socket and connect a con-

sumer, e.g. a lamp, to the outlet of the Unio-868. 

The indicator light (LED) 

2-coloured  

green and orange 

 

Operating button for  

manual mode 

 

Outlet for consumers up to 

2300 VA 

3.7  Operation (use) 

3.7.1  Status display of the Unio-868 

The status display of the indicator lamp on the top of the 

hosing signals different operating conditions of the switch-

able outlet. 

Status  

indicator  

Operating condition 

LED off 

OFF

LED green 

ON

. Unidirectional configuration 

LED orange 

ON

. Bidirectional configuration 

3.7.2  Direct operation by button at the Unio-868 

The connected consumer can be switched directly by push-

ing the operating button (switching condition switches from 

ON

 to 

OFF

 or from 

OFF

 to 

ON)

Summary of Contents for Unio-868

Page 1: ...181112301_EN_1015 0682 Operating instructions translation Keep the operating instructions in a safe place Unio 868 289800006...

Page 2: ...ts Contents 1 General information 4 1 1 Notes on the Operating Instructions 4 1 2 Standards and Directives 5 1 3 Intended use 5 1 4 Warranty and liability 6 2 Safety 7 2 1 General safety instructions...

Page 3: ...sted from the manufacturer at any time No claims may be as serted against the manufacturer as a result of the preceding sentence Deviations from text or picture statements are possible and depend on t...

Page 4: ...by the customer Non intended use of the Unio 868 Improper commissioning or operation of the Unio 868 Structural modifications to the Unio 868 without the writ ten consent of the manufacturer Operatio...

Page 5: ...ming any activities 2 3 Safety instructions for operation You have to check the casing and the connected con sumers for damage prior to the commissioning and regularly afterwards as well Never commiss...

Page 6: ...cannot send any message back to the transmitter It is also not possible to transmit radio signals from radio receiver to radio receiver 3 6 Preparations for operation WARNING Danger of injury due to e...

Page 7: ...and or a clock switching command is to be used to revoke the twilight switching condition Double commands double UP or double DOWN are treated like single running commands UP or DOWN This means that t...

Page 8: ...he switch ing condition ON or OFF may be taught in in any assign ment to the UP or DOWN buttons of the Unio 868 Teaching in switching condition ON Push the button UP or DOWN once while the light is fl...

Page 9: ...tween the transmitter and the Unio 868 or remove obsta cles between the transmitter and Unio 868 3 Switch off or remove fault sources Fault Cause Remedy The connected consumer is not supplied with pow...

Page 10: ...d electronic components Disposal and recycling of electric and electronic compo nents must comply with the applicable national laws and regulations The Unio 868 must be supplied to orderly disposal ac...

Page 11: ...20 DE elero GmbH...

Reviews: